Filter cartridges
The cooling air for canopy and bench is filtered.
Your sunbed is equipped with filter cartridges and
continuous-service filter inserts. Therefore, purchase
and replacement of conventional filter pads are
not required. Clean the filter inserts after approx.
100 hours of operation, depending on the local
circumstances. Vacuum the filter inserts or use a
dishwasher.
Bench
Canopy
There are four filter cartridges each in the canopy
and in the bench part.
NOTE
Take the opportunity and check and clean the
heat exchangers of the air-conditioning unit (See
also the chapter “Maintenance/Ventilation and air-
conditioning”). Soiled heat exchangers substantially
reduce the performance of the air-conditioner.
FILTER CARTRIDGES IN THE BENCH PART
㉔
Page
42
Open the bench part.
㉔
Open the lock of the filter insert.
⇒
Remove the filter insert.
FILTER CARTRIDGES IN THE CANOPY PART
㉕
Page
42
Fold down the canopy pane.
㉕
Open the retaining clamp of the cartridge.
⇒
Remove the filter insert.
When installing the insert, make sure that the
honeycomb grill is directed towards the inside.
Canopy drive
4
PH2
10/13
19
PH2
↵
Service the wire ropes after
each tube replacement in order
to guarantee a trouble-free
operation of the drive.
SERVICING THE CANOPY DRIVE
⇒
Test the canopy drive. The canopy must lock
in place in all positions. If it does not, the can-
opy springs must be tensioned
㉗
㊳
.
⇒
Check the ropes of the canopy drive. Should
individual wires be frayed, replace the rope
immediately.
⇒
Grease the rope in the area of the return pulley
with copper crease or adhesive lubricant
HHS-2000 (KBL 1200024000).
M a n u a l e o p e r a t i v o
|
megaSun 6700 - 6800 - 6900
48
Summary of Contents for megaSun 6900 alpha deluxe
Page 1: ...MANUALE OPERATIVO...