System messages
ERROR MESSAGES
All error messages must be acknowledged with the
OK
key!
No.
Status message
Description
Remedy
004
Mains frequency off limit.
Safety shutdown!
A deviation was detected in the mains
frequency. Device has been switched off
for safety reasons.
Restart the control unit. Contact service after the third
unsuccessful restart.
005
Canopy open. Please close
to return to normal operation.
Contact of the canopy pane and/or of the
filter cartridge cover has triggered.
Close canopy pane, check filter cartridge cover and
contacts.
006
Side open. Please close to
return to normal operation.
Contact of the side pane has triggered.
Close the side pane and check the contact.
007
Bench open. Please close to
return to normal operation.
Contact of the bench pane has triggered.
Close the bench / bench pane and check the contact.
008
The maximum tanning time
is exceeded
Coin-box system contact longer than the
value enabled under maximum tanning
time (voltage applied).
Disconnect from the coin-box system.
009
Canopy overtemperature.
Please check the
ventilation system.
Canopy overtemperature.
Let the tanning device cool down.
Check filter inserts and clean if necessary.
Check the canopy ventilation system.
012
Overtemperature shoulder
area. Please check the
ventilation system.
Overtemperature shoulder area.
Let the tanning device cool down.
Check fan freewheeling.
Check the ventilation system in the air outlet.
013
Air outlet overtemperature.
Please check the ventilation
system.
Air outlet overtemperature.
Let the tanning device cool down.
Check fan freewheeling.
Check the ventilation system in the air outlet.
044
Connection error control
board
No response from CAN-BUS Receiver.
Check / replace patch cable.
045
Connection error DALI
board
046
Connection error EC fan
board
047
Auxiliary AC-fan control
board could not be started
051
Stop switch is activated.
Start of tanning not possible.
Emergency stop button (right side cap) is
activated or jammed.
Deactivate the emergency stop button or check the
function.
052
DALI board could not be
started.
Defect of the DALI circuit board.
Contact your customer service.
054
Connection error AC fan
board
No response from CAN-BUS Receiver.
Check / replace patch cable.
055
Control board could not be
started
Defect of the control board.
Contact your customer service.
Operating instructions
| 1/2
| megaSun K5/K6/K7 PRODUCT SERIES
45
Summary of Contents for MegaSun K7S
Page 1: ...OPERATING INSTRUCTIONS PART 1 2 PRODUCT LINE...
Page 2: ......
Page 52: ...Remarks Operating instructions 1 2 megaSun K5 K6 K7 PRODUCT SERIES 52...
Page 53: ...Remarks Operating instructions 1 2 megaSun K5 K6 K7 PRODUCT SERIES 53...
Page 54: ...Remarks Operating instructions 1 2 megaSun K5 K6 K7 PRODUCT SERIES 54...
Page 55: ......