ERROR MESSAGES
After the error has been eliminated, all error messages must be acknowledged by pressing
START
on the interior display
.
No.
Status message
Description
Remedy
01
Excess temperature bimetal
canopy
Bimetal switch triggers.
Check the air-intake/air-discharge system. Let the
sunbed cool down.
02
Maximum
tanning time!
Enabling signal from coin-box system
comes in longer than the time value
approved under “Maximum tanning time”
(voltage remains connected)
Disconnect from the coin-box system.
03
Excess temperature exhaust
fan, please check
Bimetal switch in the fan triggers.
Make sure the fan runs freely. Check the air-intake/air-
discharge system. Let the sunbed cool down.
04
Connection
fan
speed
control faulty
Faulty communication between Mainboard
and fan-speed control.
Check / replace the patch cable.
08
Canopy pane open, please
close
Contact of the canopy pane has triggered.
Close the canopy pane and check the contact.
10
Bench / bench pane open,
please close
Contact of the bench pane has triggered.
Close the bench / bench pane and check the contact.
12
KBL7 Hardware error Input-
Controller
Mainboard defective.
Contact your Customer Service.
13
Maximum write cycle fl ash
memory reached
Maximum write cycle fl ash memory rea-
ched.
Contact your Customer Service.
14
Error! SD card read error
(CRC fault)
Update via SD card failed (CRC fault).
SD card check / replace.
15
Error! no access to the SD
card
Update via SD card failed (access error).
SD card check / replace
17
Parameter
storage
not
found, please connect and
restart
Parameter storage not found, please con-
nect and restart.
Check connector parameter storage. If necessary re-
place parameter storage.
18
Parameter storage no valid
serial number
Parameter storage no valid serial number.
Contact your Customer Service.
19
CAN-BUS: Interior display
V1 is incompatible
CAN-BUS operators incompatible.
Use CAN-BUS operaters V2.
20
CAN-BUS: preSelection dis-
play V1 is incompatible
21
CAN-BUS: audio module full
V1 is incompatible
22
CAN-BUS: RGB module V1
ist incompatible
23
Parameter storage write er-
ror
Parameter storage write error.
Check connector parameter storage. If necessary re-
place parameter storage.
24
Parameter storage read error
Parameter storage read error.
Check connector parameter storage. If necessary re-
place parameter storage.
25
Frequency detection: detec-
tion failed!
Frequency detection failed.
Restart the controller. Contact your Customer Service
after the third unsuccessful restart.
26
Frequency detection: po-
wer supply connection faulty
(connector X6/E6)!
Frequency detection failed. No mains vol-
tage.
Check mainboard connector X6/E6.
Summary of Contents for megaSun Optima
Page 1: ...Utilisation et Maintenance ...
Page 2: ......
Page 52: ...U t i l i s a t i o n e t M a i n t e n a n c e 52 Remarques ...
Page 53: ...U t i l i s a t i o n e t M a i n t e n a n c e Optima 53 Remarques ...
Page 54: ...U t i l i s a t i o n e t M a i n t e n a n c e 54 Remarques ...
Page 55: ......