O p e r a t i n g I n s t r u c t i o n s
|
megaSun P9
PRODUCT LINE
30
Part
Application
Cleaning and disinfection activities
Interval
①
Bench pane & handles
Directly on the
surface
• Use a suitable cleaning and disinfectant agent (e.g.
megaClean plus) and dilute it according to the manu-
facturers information.
• Use a soft, only slightly moistened lint-free cloth!
• For thorough cleaning and disinfection, the product
must be allowed to remain in contact with the surface
being cleaned and disinfected for a specified amount
of time. This specified amount of time depends on
the cleaner/disinfectant which is used. Follow the
directions for use of the cleaner/disinfectant.
• Then remove the remaining cleaning and disinfecting
agent.
After each session
②
Control panels
③
Canopy pane and side
pane
Directly on the
surface
④
Smartphone
placement area
⑤
Protective goggle and
neck pillow
⑥
Air Filter inserts
-
Remove the inserts and rinse out under running water.
100 operating hours
⑦
Condensate canister
-
Empty the condensate canister if a corresponding mes-
sage is displayed at the interior control panel.
-
Tubes
Remove tubes and clean them with a damp chamois.
200 operating hours
UV filter panes, facial-
and shoulder tanner as
well as LED boosters
Clean them with a damp chamois.
Chromed parts
-
Clean with a damp chamois and a cleaning agent for
acrylic plastic (antistatic).
When required
Plastic surfaces and
varnished surfaces
-
Clean with a damp soapy cloth. Never clean with a dry
cloth!
When required
CLEANING AND DISINFECTION PLAN
⑥
①
②
③
⑤
⑥
④
⑦