M a n u a l e o p e r a t i v o
|
megaSun Shuttle 360°
10
Connecting the external timer
Connect the external timer (e.g. coin box, studio
control) according to the instructions supplied with
the timer. The following diagram shows the wiring
requirements with regard to the timer.
Wiring on the coin box/external timer
PE
L
1
2
N
3
4
5
remote st
art
enable
Outlet of the coin-box cable
on the rear of the unit
Connecting the channel
selection
The following diagram shows the wiring of the channel
selection on the audio equipment’s side.
Outlet of the cable for an
external audio source/
channel selection on the
rear of the unit
Wiring on the audio system of the stud
PE
1
2
3
4
5
V
olume -
Control volt
age
Puls Coding
channel selection -
channel sel
V
olume +
PE
1
2
3
4
5
Control volt
age
BCD Coding
channel selection
channel selection
Wiring on the audio system of the stud
Connectors on the Shuttle
360°
1
AquaCool liquid
2
Audio connection
3
Mains connection
4
Monitoring of liquid level in the aquaBox
5
Connection of external timer (coin box)
Connectors on the aquaCool
box
1
Monitoring of liquid level in the aquaBox
2
AquaCool liquid
aquaCool Box/Shuttle 360°