background image

Bruksanvisning

Summary of Contents for megaSun Tower Optima

Page 1: ...Bruksanvisning...

Page 2: ......

Page 3: ...ept any liability for nor do we guarantee the accuracy and or completeness of the information Technical equipment and versions of the devices are in accordance with the legal prescriptions of the resp...

Page 4: ...box connections 13 Connections aquaCool box tower 13 Oppstart 14 Bruksfunksjoner 14 Solingsveiledning 15 Instructions for the user 15 Solingstider 16 Solingsdrift 17 Start solingen 17 Betjening under...

Page 5: ...g til monteringsstedet Til dette kan du for eksempel bruke en l ftearm Avhengig av hvor tunge komponentene er kan det v re n dvendig v re flere personer for l fte dem Avhending av gamle sol senger Det...

Page 6: ...e R rbetegnelse EKSEMPEL MEGASUN TOWER OPTIMA R r 48 x ultimate 1902 R 180W 4 x Collagen plus 1 2 36 PLASSERING P bildet nedenfor ser du hvor R rbetegnelse er plassert Typeskilt EKSEMPEL MEGASUN TOWER...

Page 7: ...meter p 5 mm eller mer og personer med mer enn 16 f flekker med en diameter som er st rre enn eller lik 2 mm Hvis du er i tvil m du ta kontakt med en lege Personer som har v rt alvorlig solbrente som...

Page 8: ...e gyldige normer Det er absolutt n dvendig ta hensyn til service intervallene som er oppgitt i vedlikeholdsplanen Spesielle safety advice Skiltet som er avbildet nedenfor er vedlagt og m monteres p ve...

Page 9: ...OR OPENED 1 Door 2 Door handle 3 Grab handle left hand side 4 Facing of unit lighting at top crown 5 Top crown 6 Display 7 Rubin collagen booster 8 Collagen tubes 9 Lateral part right hand side 10 Flo...

Page 10: ...Technical data A residual current operated circuit breaker RCD with short time delay is absolutely required KBL AG recommends the following type KBL 3200 0770 00 type Typ ABB F 204 A 40 0 03 AP R Shou...

Page 11: ...coin box external timer 6 door contact Connectinganexternalaudiosource The cinch marked in the illustration is connected to the external audio source where the line out of the sound player or the hea...

Page 12: ...nd side of the tower To avoid overdrive select the level adjustment accordingly The level setting depends on the strength of the external signal and should be carried out by a service engineer Externa...

Page 13: ...ctions 1 2 3 5 4 1 aquaCool liquid 2 aquaCool air blue 3 Aroma 4 Mains voltage aquaCool box 5 Data cable Tower aquaCool Box Connections aquaCool box tower aquaCool box Tower B r u k s a n v i s n i n...

Page 14: ...llers ikke kan oppn s en virkning Oppbevar denne brukerh ndboken p et sted hvor det er enkelt finne den Bruksfunksjoner De tre forskjellige bruksfunksjonene er beskrevet nedenfor STANDBYMODUS Enheten...

Page 15: ...det bare mulig bli brunere ved overskride anbefalt solmengde Dette m du unng UV str ling fra solen eller UV enheter kan f re til uopprettelig skade p hud eller yne Disse biologiske reaksjonene avhenge...

Page 16: ...Vedlikehold r rutstyr se tabellen Tekniske data EU SOLINGSPLAN iht UV type III og 0 3 W m2 iht EN 60335 2 27 Hudtyper I II III IV V VI 1 Soling 6 min 6 min 6 min 6 min 6 min 6 min 2 Soling 6 min 7 min...

Page 17: ...tiden kan solingen startes yeblikke lig manuelt med START tasten Betjening under solingen Under solingen har du mulighet av styre solariets funksjoner p det Kontrollpanelet Her har du spesielt god adg...

Page 18: ...riable betjeningsdelen Ved trykke p en av pil tastene over eller under skifteindikatoren indikeres alle tilgjengelige funksjoner i rotasjonsprinsipp Disse kan du koble inn eller ut og s fremt mulig ka...

Page 19: ...triggered Aquacool Det g r ikke an stoppe en forst v ningsprosess som er p gang G r aquaCool lageret snart tomt indikeres dette med respektiv melding p display i standby modus Fra f rste melding indi...

Page 20: ...ing er at det finnes mer enn en studio kanal MP3 ekstern AUX A line connection has been integrated into in the head area near the interior display Herkandukobletilhodetelefonenfradittegetmusikk appara...

Page 21: ...mply enter the corresponding sequence of numbers on the display 1 2 3 4 5 0 9 8 7 6 Switching the decorative lighting on and off 5 0 5 NOTE The connection times of the decorative lighting can be set i...

Page 22: ...nd off and to modify values Press 3 STORE to save all modifications made in all menu items Press 8 EXIT to go back to the previous menu level or to exit the service menu ON STORE UP EXIT DOWN OFF R E...

Page 23: ...r the changes you made See also chapter Service Menu Timeout By pressing the STORE button you save all changes you have made in all menu items 3 By pressing 8 EXIT you go back to the previous menu lev...

Page 24: ...daption Dynamic volume adaption Treble MP3 USB High bass MP3 USB Low bass MP3 USB Volume adaption Studio Line In Treble Studio Line In High bass Studio Line In Low bass Studio Line In 5 AQUA aquaCool...

Page 25: ...o avoid operating errors read through the basics at the begin ning of the Service Menu section Always remember to save your settings by pressing STORE All menu items that comprise further submenus are...

Page 26: ...OFF B OFF Switching cycle A Switching cycle B Friday 08 30 12 00 14 30 22 00 A ON A OFF B ON B OFF ENVIRONMENT 04 05 TIMER DEKOLIGHT press ENTER Entering switching times for the decorative lighting T...

Page 27: ...ettings by pressing STORE Not available in this system 2 sec reset HOUR METERS 03 04 Operating hours collagen tubes Indicates the number of tanning sessions sunbaths and includes a reset function 2 se...

Page 28: ...ernal Activates and deactivates the voice guidance system megaVoice Factory setting on on off AUDIO 02 22 megaVoice Fixes the language setting of the megaVoice system The following languages are fully...

Page 29: ...umber of studio channels If this function is active music is played nonstop i e also out of tanning sessions Factory setting off on off AUDIO 09 22 Music nonstop Allows for choosing the permanent audi...

Page 30: ...t the volume of studio line in sig nal Factory setting 00 dB 29 29 dB AUDIO 19 22 Volume adaption Studio Line In Sets the treble for studio music operation Factory setting 00 dB 14 14 dB AUDIO 20 22 T...

Page 31: ...rocess A spraying cycle of 90 seconds is started to bleed the system before commissioning after a repair operation or after a canister replacement AQUA 06 06 aquaCool initialization Start press for 2s...

Page 32: ...sday ON OFF Friday ON OFF Saturday ON OFF Sunday ON OFF Swichung cycle Friday 08 30 20 00 ON OFF AROMA 06 07 TIMER AROMA press ENTER Entering switching times for the Aroma Timer The submenu is invoked...

Page 33: ...options from 0 to 9 0 off 1 8 Permanent colour selection 9 Rotation automatic change of colour in a cycle of 15 seconds Factory setting 9 0 9 RGB 01 01 RGB mode EASYCARE 01 03 SETTINGS press ENTER In...

Page 34: ...TER SUBMENU SERVICE MODE Service mode without tanning Service mode with tanning Troubleshooting mode The service mode is switched on for 30 minutes The mains voltage is connected Error notifications a...

Page 35: ...2s Attention All unsaved changes will be discarded Lists the latest 99 events error codes info messages Detailed information is available by pressing the Start button Example no time date code tannin...

Page 36: ...D RH NDTAK Bruk helst det spesielle vaske og desinfeksjonsmiddelet megaClean fra KBL for rengj ring av akrylglassplater og h ndtak som blandes med vann i forholdet 1 13 LAKK OG KUNSTSTOFFDELER Bruk en...

Page 37: ...ons for cleaning and care must be observed The outer surface can be cleaned without any preparatory works The panes are dismantled as follows Push the pane centrically towards the tubes e g with your...

Page 38: ...pulling it out To clean the tubes use warm water and a chamois Do not use any aggressive detergents or agents con taining alcohol When installing new tubes replace the starters first Installing the tu...

Page 39: ...energy saving lamps Reattach the door panel LATERAL PARTS Dismantle the acrylic pane in the respective lateral part as described in section Cleaning and replacing the acrylic panes Remove the two fro...

Page 40: ...n regarding supported card sizes as well as file system and MP3 formats The card contains two directories Pop and Voice Within the Pop directory you can add or delete audio files as you desire These a...

Page 41: ...canister is empty corresponding messages are displayed and aquaCool switches off shortly afterwards Unscrew the lid Keep the hose end including the lid in a clean plas tic bag while replacing the can...

Page 42: ...wn the aquabox again Replacing the aquaCool nozzles After 1000 hours of operation the aquaCool nozzles have to be replaced in order to ensure that aquaCool stays fully operative and efficient The inst...

Page 43: ...rror no access to the SD card Update via SD card failed access error SD card check replace 17 Parameter storage not found please connect and restart Parameter storage not found please con nect and res...

Page 44: ...age by pressing START If the fault persists contact your Customer Service 213 SD card missing No SD card in the audio module Insert an original SD card See chapter Recording to an SD card Removing the...

Page 45: ...K Automat 3x25A med FI RCD Protective class IP20 Nominell effekt 9900 W Utbl sningsluft Ventilator Tverrsnitt 300 mm Min ventilasjonseffekt 2000 m3 h Avtrekksr r 300 Apparatdata megaSun Tower Optima i...

Page 46: ...gyldige s lenge systemet brukes med det originale settet med r r 160 R 32 3 2 Forhold for NMSC effektiv UV str ling 320nm und 320nm NMSC Non Melanom Skin Cancer ikke melanom hudkreft Erytema effektiv...

Page 47: ......

Page 48: ...KBL AG Ringstra e 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 E Mail megaSun kbl de www kbl de...