08/2017
DANGER
Live parts
Danger of life or fatal injury due to electric shock when
touching live parts.
• Switch neutral
• Secure against reconnection
• Check for neutrality
• Ground and short-circuit
• Cover or shield any adjacent live parts or compo-
nents
Attention
The tanning device may only be assembled, installed,
upgraded or repaired by qualified, trained and author-
ized service technician.
3. General electrical faults
Cables and connections fault-free
Make sure, that
• all cables in the tanning device have a fault-free
contact to their connectors.
• all loose wires in the tanning device are properly
insulated.
• no conductors or connections have discolorations,
deformations or melting tracks due to thermal
effects.
Attention
Any fault must be fixed before putting back the
tanning device into operation.
The service of the tanning device may only be
carried out by qualified, trained and authorized
service technician.
- Faulty wiring can lead to electrical overstress and,
as a result, damage the tanning device!
3.1
Approved starters installed
Make sure that the correct starters are installed
and make sure that they are properly seated in their
sockets.
Use only OEM spare parts:
Solar ÖKO82 (4 - 230W Single)
200-250 Vac 50/60 Hz (-5
0
C to +80
0
C)
KBL item no.: 3200304120
- The use of unsuitable starters can lead to electri-
cal overstress and, as a result, damage the tanning
device!
Approved ballasts installed
Ensure that the correct ballasts are installed and
make sure that they are correctly installed and that
the connection cables are properly screwed into the
clamps.
Use only OEM spare parts:
Cosmedico cosmopower (74222)
225W / 220V~60Hz
KBL item no.: 4200254211
KBL approved alternative:
May & Christe D225-24.2-6
225W-230W / 220V~60Hz
- The use of unsuitable ballasts can lead to electri-
cal overstress and, as a result, damage the tanning
device!
3.2