Reset -> after having exchanged the Aroma tin.

2 sec. = reset

AROMA 

  02/07

Aromastatus reset

> Reset: press `-` for 2s

Defines the aroma cycle time (spraying time + 
spraying interval). Only active in systems without 
aquaCool or disabled aquaCool.  If „manual“ is 
selected, by pressing the aquaCool- or Aroma plus 
button a spray cycle can be triggered.

Factory setting

: manuel

 

 

          >

> manuel

> 1 .. . 5 (min)

AROMA 

  03/07

Cycle time

The cabinet scent release can be set at intervals, 
controlled by a door contact switch, or completely 
deactivated. 

Factory setting

: off

> Door contact            >

> Intervall

> off

AROMA 

  04/07

Aroma cabin automatic

For interval operation of the cabinet scent released, 
the number of scent releases per hour can be set 
here.

Factory setting

: 3

 

 

          >

> 1 .. . 6

AROMA 

  05/07

Aroma cycles per hour

The menu item „TIMER AROMA“ offers you 
a switching cycle for each day of the week.

NOTE - SWITCHING CYCLES
Using the setting „monday-sunday“, the switching 
cycle will be the same for each day of the week.

Week

Switching cycle

Monday 
- Sunday

ON

OFF

Day

Switching cycles

Monday

ON

OFF

Tuesday

ON

OFF

Wednesday

ON

OFF

Thursday

ON

OFF

Friday

ON

OFF

Saturday

ON

OFF

Sunday

ON

OFF

Swichung cycle

Friday

08:30

20:00

ON

OFF

Summary of Contents for Tower space 2000

Page 1: ...TANNING DEVICE TANNING DEVICE ASSEMBLY INSTRUCTIONS MENU SETTINGS ...

Page 2: ......

Page 3: ... of the information EXPORT Technical equipment and versions of the devices are in accordance with the legal prescriptions of the respective country of destination Export to the European Union of the KBL products listed in this guide or operation of the systems in these countries are not permitted KBL does not accept any manufacturers liability in case this direction is not adhered to It is express...

Page 4: ...nnections Initial operation 26 5 1 Class I ME equipment 26 5 2 Overview supply connections 26 5 3 Connecting the mains voltage 26 5 4 Connecting an external audio source 27 5 5 Level adjustment studio music 27 5 6 Operation using different audio sources 27 5 7 Bluetooth connection 28 5 8 Connecting the channel selection 29 5 9 Connecting the external timer 29 5 10 aquaCool box connections 30 5 11 ...

Page 5: ...ealth This symbol indicates the danger of pinching When assembling heavy components you can pinch your fingers or hands This symbol indicates the danger of burns from hot lamps and housing parts If the tanning device was operated before being opened lamps and hous ing parts may be hot This symbol indicates that damages may occur at the tanning device at the material or at the environment Danger du...

Page 6: ...rks that are too short Use only sufficiently long forks The box with the tanning device components is mounted on a pallet Insert the forks carefully into the openings of the pallet Lift the load by a few centimeters Transport the load carefully to the place of installation 1 4 2 OTHER MODES OF TRANSPORT If a forklift truck cannot be used for transport the box must be unpacked and the parts inside ...

Page 7: ...ety equipment must not be disabled or removed The tanning device must only be operated when in perfect working condition Never operate the tanning device with the outer covers or acrylic panes removed This tanning device must be operated with an external timer that is listed in compliance with UL 917 Before carrying out any work the tanning device must be disconnected from the mains voltage DANGER...

Page 8: ...ite and dimensions In dry rooms booths with sufficient airing Even floor with sufficient load capacity Relative humidity 70 Room temperature 30 0 C 86 0 F Minimal room height 2270 mm 89 37 inches Only on a non combustible basement 3 1 Dimensions 85 83 in 55 12 in 55 31 in 77 28 in ...

Page 9: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 9 3 2 Distances 2 0 i n 20 in 20 in 1 1 0 i n 3 54 in 2 83 in 89 37 in 20 in ...

Page 10: ...haust air is to be let out on the lower side the exhaust air grid has to be exchanged with the exhaust air cover and the fan accordingly 4 3 Option Alteration for central exhaust air If the tanning device has to be connected to the central exhaust air the exhaust air grid has to be exchanged with the exhaust air socket 4 4 Assembling the tanning device The line of sight used in the text is from th...

Page 11: ... o n s KBL Tower space 2000 11 Place the back plane into the corresponding pits Fix one angle at the right and one angle at the left side of the back plane Fix the box with the fan Observe the minimum and maximum height when adjusting ...

Page 12: ... b l y I n s t r u c t i o n s KBL Tower space 2000 12 Place the side plates into the pids and adjust side plates with the back plane even and flush Fix the side plates according to the picture Adjust with level ...

Page 13: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 13 ...

Page 14: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 14 On both sides lead the cable harness from the back plane through the sickel shaped metal to the side plate Fix it in the lace ...

Page 15: ...the wire harness Here ensure that the bushing is installed with flat side positioned as in the illustration and attached with 2 M5 x 6 mm slotted screws Then place the wire harness in the gap With the included bushing attach the door to the lower crescent Here ensure once again that the flat side is positioned as in the photo Attach this bushing with 2 M5 x 6 mm slotted screws as well ...

Page 16: ... m b l y I n s t r u c t i o n s KBL Tower space 2000 16 Measure the distance between top edge of the side plate and top edge of the door The space should be max 10 mm at the left and the right side max 10 mm ...

Page 17: ...nge the alignment of the lateral parts towards each other must be checked page 9 If the limit is not observed in spite of a correct alignment of the parts the alignment is done by adapting the front feet of the tanning device instead Please note that their minimum height is 48 mm the maximum height is 60 mm ...

Page 18: ...ce 2000 18 Place the ceiling part on top of the tanning device and fix it according to the picture When tightening the screws one person lifts the door up slightly while the second person fastens the top of the tanning device Don t jam the cable harnesses ...

Page 19: ...ght side pull the following cables and hoses out of the ceiling part five hoses 2x aroma 2x aquaCool 1x air for aquaCool Harness with molex connector music one cable with jack plug line in one cable with RJ22 plug display Harness with connectors X7 and X4 X2 Connect 2x aroma ...

Page 20: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 20 2x aquaCool liquid and 1x aquaCool air BLUE 1x display RJ22 and 1x line in jack plug ...

Page 21: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 21 1x music molex connector Connect X 2 X 4 with X 4 X 7 only for devices with decorative lighting in the ceiling part ...

Page 22: ...c t i o n s KBL Tower space 2000 22 Hook in the ballast boards at the left side plate The boards with more ballasts as with model with 52 tubes are placed at the left side Connect the cables in the left side plate X 2 X 4 mit X 2 ...

Page 23: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 23 Hook in the side and door coverings ...

Page 24: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 24 Fix the door handle ...

Page 25: ...A s s e m b l y I n s t r u c t i o n s KBL Tower space 2000 25 Fix the inside handles according to the picture Attach the door spring between the two spring seats ...

Page 26: ...d local regulations The connection work and replacement of the power supply cord must only be performed by qualified trained and authorized service techni cians The connection to the 3 x 220 V mains must be protected by maximum over current protection For Canada a Class A ground fault circuit interrupter GFCI has to be used Further information can be found in chapter Technical data CONNECTION REQU...

Page 27: ...t you use the right cable for the power supply 5 4Connectinganexternalaudio source The cinch marked in the illustration is connected to the external audio source where the line out of the sound player or the headphone loudspeaker jack are available for connection 5 5 Level adjustment studio music The voice audio system components are installed in the back part of the tanning device The potentiomet...

Page 28: ... an MP3 player an iPod etc Use a stand ard 3 5mm jack cable included if the music option has been ordered Connect the jack plug to the earphone jack of your player Then select MP3 ext as the audio source from the inerior control panel of the tanning device before you start playing your own tracks from the player The tracks can only be selected via the user s own player The volume can be controlled...

Page 29: ...ot started within 6 minutes COMPATIBILITY OF BLUETOOTH DEVICES KBL GmbH attaches great importance to hard ware compatibility Due to the large number of manufacturers KBL can not guarantee a 100 compatibility In rare cases it may happen that a bluetooth connection can not be established CORRECTIVE ACTION Each bluetooth device offers a list of paired devices Delete the older entries in this list whi...

Page 30: ...ated in the expo sure schedule must be entered at the External Studio Timer Information on how to enter the expo sure time can be found in the operating instructions of your Studio Timer 5 10 aquaCool box connections 1 2 3 5 4 1 aquaCool liquid 2 aquaCool air blue 3 Aroma 4 Mains voltage aquaCool box 5 Data cable Tower aquaCool Box 5 11 Connections aquaCool box tower aquaCool box Tower 5 12 Initia...

Page 31: ...anel are allocated double functions In addition to the standard operating elements they stand for numbers that in standby mode provide access to standby and service functions Simply enter the corresponding sequence of numbers on the interior control panel 1 2 3 4 5 0 9 8 7 6 6 2 Invoking the service menu CALL SERVICE MENU START WINDOW 1 6 1 SERVICE MENU START WINDOW SERVICEMENU Enter Servicemenu C...

Page 32: ...e in all menu items Press 8 EXIT to go back to the previous menu level or to exit the service menu R E S E T ON STORE UP EXIT ENTER DOWN OFF RESET SERVICE MENU BASIC OPERATION The service menu is divided into the main menu and subordinate groups of functions If you choose a menu item e g AUDIO you will get access to all functions related to this item Select the desired function group from the main...

Page 33: ...ot take over the changes you made See also chapter Service Menu Timeout By pressing the STORE button you save all changes you have made in all menu items 3 By pressing 8 EXIT you go back to the previous menu level or you exit the service menu 8 SERVICE MENU TIMEOUT After performing your last operating action you have 2 minutes left to save the changes you have made Then a prompt appears and all ch...

Page 34: ...amic volume adaption Treble MP3 USB High bass MP3 USB Low bass MP3 USB Volume adaption Studio Line In Treble Studio Line In High bass Studio Line In Low bass Studio Line In AQUA aquaCool aquaCool spray time Cycle time aquaCool start test cycle aquaCool endurance test aquaCool start initializatio AROMA Aroma Aroma status reset Cycle time Aroma cabin automatic Aroma cycles per hour TIMER AROMA Aroma...

Page 35: ... window can be done directly with the CODE 2 In this case all CODE 2 protected menu items are immediately activated The factory set CODE 2 remains valid even if an individual CODE 2 is set Individual CODES are not reset by loading the factory settings The one time input of CODE 2 immediately activates all protected menu items In the following chapter you will recognize CODE 2 protected menu items ...

Page 36: ...mer decorative lighting offers you two switching cycles A and B for each day of the week NOTE SWITCHING CYCLES Using the setting monday sunday the switching cycle will be the same for each day of the week Week Switching cycle A B Monday Sunday A ON B ON A OFF B OFF Day Switching cycles A B Monday A ON B ON A OFF B OFF Tuesday A ON B ON A OFF B OFF Wednesday A ON B ON A OFF B OFF Thursday A ON B ON...

Page 37: ...nday ENVIRONMENT TIMER0 1 04 Monday AON 00 00 23 59 XX XX Save settings by pressing STORE Set the time SUBMENU TIMER DECOLIGTH Not available in this system ENVIRONMENT 05 05 Maximum tanning time Displays the total operating hours HOUR METERS 01 04 Operating hours overall 0788h Displays the total operating hours of the tubes and includes a reset function and set function to set the value in steps o...

Page 38: ...urce Factory setting MP3 internal Studio Line In MP3 internal MP3 external PRESELECTION 02 06 Audio Specifies the start setting of the voice guidance system Factory setting on on off PRESELECTION 03 06 Voice megaVoice Not available in this system PRESELECTION 04 06 Aircon Aircondition Defines the start setting of Aroma Factory setting on on off PRESELECTION 05 06 Aroma Specifies the start setting ...

Page 39: ...he head end for units from standard line level to low loudspeaker levels MP3 player iPod etc Factory setting on on off AUDIO 06 22 MP3 Line In Allows for the change over between pulse code and BCD code mode with the Studio music signal pending and deactivates the external channel selection Factory setting BCD bcd puls code off AUDIO 07 22 Studio channel selection If BCD has been preselected the nu...

Page 40: ...etting 07 dB 09 09 dB AUDIO 14 22 megaVoice volume adaption Dynamic volume adaption on off Factory setting on on off AUDIO 15 22 Dynamic volume adaption Sets the treble for MP3 USB operation Factory setting 14 dB 14 14 dB AUDIO 16 22 Treble MP3 USB Sets the high bass for MP3 USB operation Factory setting 08 dB 14 14 dB AUDIO 17 22 High bass MP3 USB Sets the low bass for MP3 USB operation Factory s...

Page 41: ...l or Aroma plus button a spray cycle can be triggered Factory setting manuel manuel 1 5 min AQUA 03 06 Cycle time Starts the aquaCool test 1 cycle AQUA 04 06 aquaCool start testcycle Start press for 2s Starts the aquaCool endurance test After having selected and stored the on setting you must leave the service menu and start a tanning session Attention aquaCool will continue to spray permanently d...

Page 42: ...olled by a door contact switch or completely deactivated Factory setting off Door contact Intervall off AROMA 04 07 Aroma cabin automatic For interval operation of the cabinet scent released the number of scent releases per hour can be set here Factory setting 3 1 6 AROMA 05 07 Aroma cycles per hour The menu item TIMER AROMA offers you a switching cycle for each day of the week NOTE SWITCHING CYCL...

Page 43: ...ay OFF 00 00 23 59 XX XX Save settings by pressing STORE Set the time SUBMENU TIMER AROMA Starts the Aroma test 1 cycle AROMA 07 07 Aroma start testcycle Start press for 2s Not available in this system AIR CONDITIONING 01 02 Aircon air conditioning Specifies the start speed setting of the body fan at the beginning of the tanning Factory setting 2 1 9 AIR CONDITIONING 02 02 Start level body fan Not...

Page 44: ... code level 1 press SET to enter code S E T S T O R E Service Code Level 1 entry repeat 00000 00000 press 0 for 2s to reset the code Enter new service code 2 and repeat the entry Save settings by pressing STORE SERVICE SERVICE CODE 02 02 service code level 2 press SET to enter code S E T S T O R E Service Code Level 2 entry repeat 00000 00000 press 0 for 2s to reset the code SERVICE 03 11 BLUETOOT...

Page 45: ... and the last Software Upload SERVICE 06 11 SOFTWARE UPLOAD press enter Not available in this system SERVICE 07 11 RGB Setup SERVICE 08 11 SERVICE MODE press ENTER Submenu SERVICE MODE Invoked by pressing START ENTER SUBMENU SERVICE MODE Service mode without tanning Service mode with tanning Troubleshooting mode The service mode is switched on for 30 minutes The mains voltage is connected Error no...

Page 46: ...y be made by trained service personnel SERVICE 10 11 SOLARIUM X CODE press enter Performs a restart of the electronics SERVICE 11 11 Reboot Reboot press for 2s Attention All unsaved changes will be discarded Lists the latest 99 events error codes info messages Detailed information is available by pressing the Start button Example no time date code tanning time 001 16 44 05 01 09 0011 03 23 002 15 ...

Page 47: ......

Page 48: ...Ringstraße 24 26 56307 Dernbach Germany fon 49 0 26 89 94 26 0 fax 49 0 26 89 94 26 66 ...