background image

41

GB-Gas Euro Range

Oriental- Gas-20190620

FR

M

-P

DE

-0

3-

04

(N

YT

/R

&

D/

20

18

10

08

)

GENERAL EXCLUSIONS

Damage to control knobs and buttons.

Discoloration of components due to heat.

Drainage does not meet requirements.

Lubrication of moving parts.

Corrosion caused by the use of chemical

cleaners.

Replacement of components due to

internal contamination as a result of

spillage or accumulation of grease/food

debris due to a lack of cleaning.

Cabinet, drawer and door seals are

considered consumable items and will not

be replaced under warranty.

Light bulbs, lens covers and sticker display

are considered consumable items and will

not be replaced under warranty.

Enamel coated components if impacted

sufficiently will crack or chip, such damage

is not covered by the terms of this

warranty.

Rectification where non-Nayati specified

parts have been used.

Where user error is established.

Gas general

Poor combustion caused by lack of

cleaning.

Failure of components directly linked to

poor cleaning and/or maintenance.

Cleaning of burners jets.

Cleaning/adjustment of pilots and

thermocouples.

Correction of gas pressure to the

appliance.

Renewing of gas supply fittings external to

the appliance.

Electrical general

Resetting of safety devices including fuses

where no other fault exists.

Renewing of supply cable ends.

Fryers

Replacement of components damaged by

cooking oils due to a lack of cleaning and

care when replacing oil.

Damage to thermostats.

Steamers

Corrosion caused by high water hardness.

Damage resulting from lack of water flow to

the unit.

Induction

Chipped or damaged glass not reported at

time of delivery.

Damage due to blocked or missing air filters.

Damage to the generator due to wrong pan

type/size used.

Gas Charcoal grills and salamanders

Impact damage caused by the user due to

misuse outside of the design scope.

Chargrill Radiant covers

Radiant covers are considered consumable

items and may corrode if not regularly

cleaned due to prolonged contact with salt

and fats and will not be replaced under

warranty.

Damage to heaters due to failure to replace

radiant covers is not covered by the

warranty.

Heated and chilled food displays

Chipped or damaged glass not reported at

time of delivery.

Damage to components resulting from

restricted airflow to inlets and outlet.

Damage to components resulting from

accumulation of airborne particles.

Condensation on cold surfaces if units are

installed in environments beyond

specification.

Dishwashing

Corrosion caused by high water hardness.

Chemical pump due to misuse chemical

agent.

Washing accessories : basket, curtain.

Malfunction caused by high water hardness.

10. General Exclusions

G

en

er

al

E

xc

lu

sio

ns

Summary of Contents for NGER 4-60

Page 1: ...BEDIENUNGSANLEITUNG KBS Gastrotechnik GmbH Scho bergstra e 26 65201 Wiesbaden www kbs gastrotechnik de Stand Juli 2022...

Page 2: ...l Model NGER 4 60 1 Gas Burner NGER 7 70 1 Gas Burner NGER 9 60 2 Gas Burners NGER 13 70 2 Gas Burners NGER 15 60 3 Gas Burners NGER 20 70 3 Gas Burners NGER 20 60 4 Gas Burners Gas Euro Range Note Th...

Page 3: ...terials NAYATI Gas Euro Range is excellent choice to cook In order to obtain maximum benefits of this appliance please read this manual instruction carefully Please notice the warnings and safety inst...

Page 4: ...23 3 5 Water System Components 25 4 Handling and Installing 26 44 1 4 1 Packaging and Transport 27 4 2 Handling and Lifting 27 4 3 Safety Devices and Accessories 27 4 4 Position and Fixing 28 4 5 Gas...

Page 5: ...vided if necessary 1 2 Warning Signs and Symbols 1 2 1 Warning Warnings are indicated with a pictogram and a signal word The type and source of the risk as well as the consequences are described toget...

Page 6: ...n can be carried out in any sequence Instruction multiple steps An action is required here 1 3 General Information of the Appliance Nayati Gas Euro Range is an excellent cooking appliance made of stai...

Page 7: ...ives 12 months guarantee with certain conditions NAYATI will decline any claims of accidents caused by improper use disobey rules and or disobey warnings Below are cases which invalidate the guarantee...

Page 8: ...NOT use the appliance to heat non food products 9 Put the appliance in a good ventilated room 10 Before cleaning or maintaining the appliance detach the gas line and allow it to cool 11 DO NOT touch t...

Page 9: ...20 26 kW G30 23 kW G20 39 kW G30 34 5 kW G20 52 kW G30 46 kW Gas Supply Pressure G30 G31 28 30 37 mbar G30 G31 50 mbar G20 20 mbar G25 20 mbar G30 G31 28 30 37 mbar G30 G31 50 mbar G20 20 mbar G25 20...

Page 10: ...S R 1 R R R 1 R R R 1 R R Cooking Surface Wok mm 280 280 280 Number of Burners 1 2 3 Rate G20 13 kW G30 11 5 kW G20 26 kW G30 23 kW G20 39 kW G30 34 5 kW Gas Supply Pressure G30 G31 28 30 37 mbar G30...

Page 11: ...Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 3 2 Data Plate Technical plate reports the current gas setting nominal data gases table categories and pressures for other CE count...

Page 12: ...11 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 Fig 1...

Page 13: ...7 DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 EE II2H3B P 20 28 30 ES II2H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 HR II2H3B P 20 28 30 HU II2...

Page 14: ...ons of the appliance before operating it GR LU ier ce j uzst da saska ar sp k eso ajiem noteikumiem un to var darbin t tikai labi v din t vid Pirms ier ces uzst d anas un lieto anas p rliecinieties ka...

Page 15: ...e limin conform ment la r glementation en vigueur ES II2H3 G20 2H 20 mbar G30 G31 3 28 30 37 mbar Esto aparato debe ser instalado conforme a las normas vigentes y setiene que utilizer solo en locales...

Page 16: ...etjener apparatet skal du l se de relative instruktioner SE II2H3B P G20 2H 20 mbar G30 G31 3B P 28 30 mbar Denna apparat m ste installeras enligt g llande f reskrifter och f r endast anv ndas i v l v...

Page 17: ...16 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 3 3 Overall Dimension Fig 2 NGER 4 60 G Gas Connection...

Page 18: ...17 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 9 60 G Gas Connection Fig 3...

Page 19: ...18 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 15 60 G Gas Connection Fig 4...

Page 20: ...19 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 20 60 G Gas Connection Fig 5...

Page 21: ...20 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 7 70 G Gas Connection D Drain W Water Connection Fig 6...

Page 22: ...21 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 13 70 G Gas Connection D Drain W Water Connection Fig 7...

Page 23: ...22 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 20 70 G Gas Connection D Drain W Water Connection Fig 8...

Page 24: ...23 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 3 4 Component List NGER 60 SERIES Table 5 Fig 9...

Page 25: ...24 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 NGER 70 SERIES Table 6 Fig 10...

Page 26: ...s NGER 70 SERIES Table 7 NO PART CODE DESCRIPTION QTY NGER 7 70 NGER 13 70 NGER 20 70 1 GS 2305C Faucet Stop tap w Plastic Handle 2 2 3 2 PD 2458A2 Water Tap Head 2 2 3 GS 2305C1 Pin Blue Screw f Fauc...

Page 27: ...e coatings 3 Ensure gas supply is sufficient to operate this appliance 4 Install the appliance by using Qualified Gas Filter 5 Before testing put the appliance in a good ventilated room and keep all f...

Page 28: ...partly on the destination During transport fix the packaging to the means of transport securely to prevent undesirable shifting 4 2 Handling and Lifting The appliance can be handled using fork lift or...

Page 29: ...with appropriate solvent Eliminate all packaging material according to national laws 4 5 Gas Supply Connection 1 Before installing and connecting Gas Euro Range to gas supply carefully control the fi...

Page 30: ...ons carefully check the diameters and the quality of installed nozzles and gas main pressure If you want to measure the main pressure while Gas Euro Range is ON and using a pressure gauge for liquids...

Page 31: ...t the Burner 1 about 10 mm and pull from mixing chamber 3 2 Remove the fixing screw 2 This screw can be reach from below 3 Remove the complete mixing chamber 3 by turn anticlockwise from the Nozzle 4...

Page 32: ...d with liquid gas turn Nozzle C clockwise 5 Fix gas after regulating washer 11 and covering screw 10 5 1 3 Adjusting Main Burner Minimum Rate Access By Pass screw A of the gas tap after removing the h...

Page 33: ...Input Gas Type Pressure mbar Nozzle mm Pilot Nozzle mm Primary Air Adjustment H mm Air Chamber for Nozzle By pass Screw for Gas Cock mm 11 5 kW LPG G30 G31 28 30 37 1 80 0 20 12 mm Opened Full Opened...

Page 34: ...and check for leaks Properly control Gas Euro Range work according to these instructions Please check main burners cross lighting stability and flame factor 5 1 5 Install Pipe Leg 1 Put 4 pipes on the...

Page 35: ...thorized mechanic 3 User is only responsible for daily routine cleaning for maintenance 4 Qualified mechanic must do operations related to installation and maintenance according to Regulation in force...

Page 36: ...se the gas supply 6 2 3 Operating Water Faucet 1 Turn the Water Tap Faucet anticlockwise to open the Water Faucet on top panel 2 Turn the Tap clockwise to close the Water Faucet 6 2 4 Operating Water...

Page 37: ...008 6 3 Suitable Wok Type Suitable wok type which can be used for NGER 4 60 9 60 15 60 20 60 7 70 13 70 20 70 Wok size 355 457 mm 6 4 Suitable Pan Type Suitable pan type which can be used for NGER 4 6...

Page 38: ...few minutes 5 Clean the plate thoroughly with a sponge rinse with plenty of water and dry 6 Clean the burners with mild detergent or using soap and water 7 Check the burners whether the holes are clo...

Page 39: ...le clogged Check and replace 2 Burner flame yellow Primary Air setting incorrect Check and repair Burner dirty Check and clean 3 Burner does not ignite Gas valve damaged Check and replace 4 Pilot flam...

Page 40: ...39 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008 9 CE Certificate CE Certificate...

Page 41: ...40 GB Gas Euro Range Oriental Gas 20190620 FRM PDE 03 04 NYT R D 20181008...

Page 42: ...ncluding fuses where no other fault exists Renewing of supply cable ends Fryers Replacement of components damaged by cooking oils due to a lack of cleaning and care when replacing oil Damage to thermo...

Page 43: ...Code 529000 People s Republic of China T 86 750 3229028 3229218 F 86 750 3221208 Branch Offices Local Offices JAKARTA Jl Batu Ceper 55 A Jakarta Pusat 10120 Indonesia T 62 21 384 6688 F 62 21 3890 131...