background image

BEDIENUNGSANLEITUNG

KBS Gastrotechnik GmbH – Schoßbergstraße 26 – 65201 Wiesbaden

www.kbs-gastrotechnik.de 

Stand 

Juli 2022

Summary of Contents for NGETL 5-50 CE

Page 1: ...BEDIENUNGSANLEITUNG KBS Gastrotechnik GmbH Scho bergstra e 26 65201 Wiesbaden www kbs gastrotechnik de Stand Juli 2022...

Page 2: ...llation Operation and Maintenance Instructions Model NGETL 5 50 CE One Gas Soup Burner Atmospheric Burner Safety Thermocouple Gas Table Low Note The picture is illustration only We reserved the right...

Page 3: ...terials NAYATI Gas Table Low is excellent choice to cook In order to obtain maximum benefits of this appliance please read this manual instruction carefully Please notice the warnings and safety instr...

Page 4: ...ension 13 3 4 Components List 14 4 Handling and Installing 15 4 1 Packaging and Transport 15 4 2 Handling and Lifting 16 4 3 Safety Devices and Accessories 16 4 4 Position and Fixing 16 4 5 Gas Supply...

Page 5: ...vided if necessary 1 2 Warning Signs and Symbols 1 2 1 Warning Warnings are indicated with a pictogram and a signal word The type and source of the risk as well as the consequences are described toget...

Page 6: ...ut in any sequence Instruction multiple steps An action is required here 1 3 General Information of the Appliance Nayati Gas Table Low is an excellent cooking appliance made of stainless steel This ap...

Page 7: ...ives 12 months guarantee with certain conditions NAYATI will decline any claims of accidents caused by improper use disobey rules and or disobey warnings Below are cases which invalidate the guarantee...

Page 8: ...e in wet or humid room or condition such in rain or near water leaks etc 7 DO NOT use the appliance for drying clothes paper or living animals 8 DO NOT use the appliance to heat non food products 9 Pu...

Page 9: ...WxD mm 520 Rate G30 11 5 kW 9 890 kCal h G20 13 kW 11 180 kCal h Gas Connection G R 3 4 Gas Supply Pressure G30 G31 28 30 37 mbar G30 G31 50 mbar G20 20 mbar G25 20 mbar Direct Heat Emission kW 3 25...

Page 10: ...DE II2ELL3B P 20 50 DK II2H3B P 20 28 30 EE II2H3B P 20 28 30 ES II2H3 20 28 30 37 FI II2H3B P 20 28 30 FR II2E 3 20 25 28 30 37 GB II2H3 20 28 30 37 GR II2H3 20 28 30 37 HR II2H3B P 20 28 30 HU II2H...

Page 11: ...tions of the appliance before operating it GR LU ier ce j uzst da saska ar sp k eso ajiem noteikumiem un to var darbin t tikai labi v din t vid Pirms ier ces uzst d anas un lieto anas p rliecinieties...

Page 12: ...tre limin conform ment la r glementation en vigueur ES II2H3 G20 2H 20 mbar G30 G31 3 28 30 37 mbar Esto aparato debe ser instalado conforme a las normas vigentes y setiene que utilizer solo en local...

Page 13: ...etjener apparatet skal du l se de relative instruktioner SE II2H3B P G20 2H 20 mbar G30 G31 3B P 28 30 mbar Denna apparat m ste installeras enligt g llande f reskrifter och f r endast anv ndas i v l v...

Page 14: ...13 GB Gas Table Low Oriental Gas 20200130 FRM PDE 03 04 NYT R D 20200130 3 3 Overall Dimension NGETL 5 50 CE Fig 2...

Page 15: ...14 GB Gas Table Low Oriental Gas 20200130 FRM PDE 03 04 NYT R D 20200130 3 4 Component List Table 5 Fig 3...

Page 16: ...indicated by bubbles comes from the joints or pipefitting Another way is by looking at the gas counter If there is no movement on the gas counter it means no gas leakage 7 Before cleaning or maintaini...

Page 17: ...mended to install it under efficient hood which could evacuate burned gases and cooking steams Below is construction type according to National Regulations A1 Appliance without fan and does not have c...

Page 18: ...s Table Low safely take a pressure test the whole gas circuit by using leak finder spray or non corrosive foams 11 The Gas Table Low is equipped with ISO 7 1 screw thread gas connection of inches diam...

Page 19: ...1 Gas Pressure Table 6 Gas Type Gas Pressure mbar Normal Minimum Maximum Natural gas G20 20 17 25 Natural gas G25 20 18 25 LPG G30 G31 28 30 37 20 25 35 45 LPG G30 50 42 5 57 5 C Inlet pressure point...

Page 20: ...Burner 1 about 10 mm and pull from mixing chamber 3 2 Remove the fixing screw 2 This screw can be reach from below 3 Remove the complete mixing chamber 3 by turn anticlockwise from the Nozzle 4 Turn...

Page 21: ...perated with liquid gas turn Nozzle C clockwise 5 Fix gas after regulating washer 11 and covering screw 10 5 1 3 Main Burner Minimum Rate Access By Pass screw A of the gas tap after removing the handl...

Page 22: ...e 7 Nominal Heat Input Gas Type Pressure mbar Nozzle mm Pilot Nozzle mm Primary Air Adjustment H mm Air Chamber for Nozzle By pass Screw for Gas Cock mm 11 5 kW LPG G30 G31 28 30 37 1 80 0 20 12 mm Op...

Page 23: ...e contact authorized mechanic 3 User is only responsible for daily routine cleaning for maintenance 4 Qualified mechanic must do operations related to installation and maintenance according to Regulat...

Page 24: ...security Gas Control Knob to the 0 position 2 To extinguish the flame temporary turn the security Control Knob to the position At this position only Pilot flame remains lighting 3 After cooking exting...

Page 25: ...few minutes 5 Clean the plate thoroughly with a sponge rinse with plenty of water and dry 6 Clean the burners with mild detergent or using soap and water 7 Check the burners whether the holes are clog...

Page 26: ...e clogged Check and replace 2 Burner flame yellow Primary Air setting incorrect Check and repair Burner dirty Check and clean 3 Burner does not ignite Gas valve damaged Check and replace 4 Pilot flame...

Page 27: ...26 GB Gas Table Low Oriental Gas 20200130 FRM PDE 03 04 NYT R D 20200130 9 CE Certificate CE Certificate...

Page 28: ...27 GB Gas Table Low Oriental Gas 20200130 FRM PDE 03 04 NYT R D 20200130...

Page 29: ...ncluding fuses where no other fault exists Renewing of supply cable ends Fryers Replacement of components damaged by cooking oils due to a lack of cleaning and care when replacing oil Damage to thermo...

Page 30: ...dong Postal Code 529000 People s Republic of China T 86 750 3229028 3229218 F 86 750 3221208 Branch Offices Local Offices JAKARTA Jl Batu Ceper 55 A Jakarta Pusat 10120 Indonesia T 62 21 384 6688 F 62...

Reviews: