background image

100.210 - Multi Water Sampler - 12 x 50 ml - Manual 

11

 

Safety Regulations 

 
KC Denmark A/S is not, and cannot be held, responsible for any damage(s) made to equipment or to 
operators who ignore safety precautions or because of misuse or wrong operation.  
 
 

 

 

Disconnect power supply to avoid any unattended operation causing accident to personnel and 
multiple water sampler.

 

 

An expert maintenance technician fully familiar with the attendant hazards must only do all maintenance, 
inspection and repairs.  
 
Persons charged with working on the multiple water sampler and its accessories must be trained specially 
for the purpose with special abilities and experience in this area as well as being equipped with the 
appropriate tools and individual safety equipment. Failure to meet these requirements constitutes a risk 
to personal health and safety and economic damages. 
 
When working on the unit in areas, which are difficult to access or hazardous, ensure to take adequate 
safety precautions for the operator and others in compliance with the provisions of law on health and 
safety at work.  
 
Replace worn component with original spare parts.  

 

 

Rev.: February 1, 2022 - lkj 

 

 
 

 
 

 
 

 
 
 
 

 

KC

 

Denmark A/S

 

Research Equipment 

Limnology 

 Oceanography 

 Hydrobiology 

 

E-mail

sales@kc-denmark.dk

 website

http://www.kc-denmark.dk/

 

Holmbladsvej 17-19, DK 8600 Silkeborg, Denmark. Tel. +45 86 82 83 47 

Bank: Sydbank. SWIFT: SYBKDK22 - IBAN DK5070460000104832  

VAT no. DK 29 61 96 62 

 

Summary of Contents for 100.210

Page 1: ...Multi water sampler shown with accessories optional Multi Water Sampler 12 syringes each 50 ml Model 100 210 Manual KC Denmark A S Research Equipment Limnology Oceanography Hydrobiology ...

Page 2: ...nt or to operators who ignore safety precautions or because of misuse or wrong operation Item Description 1 A complete system requires the following items 100 210 The multi water sampler 60 010 Time lapse trigger incl tablet and preinstalled software 100 217 Battery cylinder 4000 m with room for time lapse trigger or 100 226 for 6000 m 100 230 Cable from battery cylinder to motor 100 234 Plug for ...

Page 3: ...e first time set the motor moves one step forward releasing a single syringe The arm A releases the syringe by pushing the pawl to a side so the spring loaded bar pulls the syringe s piston backwards allowing a sample to be taken 4 The syringes is loaded one by one by pushing the holder downwards at the same time turn the pawl to hold the bar in its lower position 5 Three syringes have been loaded...

Page 4: ...vanced electronics preventing overcharging even if connected for a long time The Subconn connectors requires to be greased with Molykote see recommendations on page 7 10 The photo shows the programming plug to the left and a dummy for the Subconn connector optional 8 The tablet comes with pre installed software for the programming Once charged replace the charger cable with the USB cable and conne...

Page 5: ...0 the sampler starts immediately after the delay If you estimates that the deployment to the desired depth takes 5 minutes you may enter the value 5 All remaining samples may have various delays between every sample You can enter an individually delay in the range of 1 min to 600 hours for every sample but keep in mind that the battery capacity may be insufficient for very huge delays which may be...

Page 6: ...100 210 Multi Water Sampler 12 x 50 ml Manual 6 Maintenance 17 Wash all parts thoroughly with fresh water For maintenance of the Subconn connectors see pg 7 10 ...

Page 7: ...100 210 Multi Water Sampler 12 x 50 ml Manual 7 ...

Page 8: ...100 210 Multi Water Sampler 12 x 50 ml Manual 8 ...

Page 9: ...100 210 Multi Water Sampler 12 x 50 ml Manual 9 ...

Page 10: ...100 210 Multi Water Sampler 12 x 50 ml Manual 10 ...

Page 11: ...pose with special abilities and experience in this area as well as being equipped with the appropriate tools and individual safety equipment Failure to meet these requirements constitutes a risk to personal health and safety and economic damages When working on the unit in areas which are difficult to access or hazardous ensure to take adequate safety precautions for the operator and others in com...

Reviews: