background image

 

The hydraulic damper 

 

18 

The multi corer has an automatic, hydraulic 
damper located at the centre. 
 
Upon lowering to the sea, the damper is filled 
up with water through the inlet 

“K”

 

 
When the multi corer hits the seabed, the water 

is forced through the outlet “L”, 

causing a delay 

before the tubes penetrate the sediment.  

 

 

 

 

Deployment 

 

19 

 

 

The multi corer is now ready for deployment. 
When the rack is outside the bulwarks, you can 
remove the safety clamps 

“1”

 
The photo shows an old model with 2 safety 
clamps. 
 
If you must remove the security clamp while 
the sampler is on deck, you must avoid an 
unattended release to protect against injury. 

 

 

 

20 

 
The sampler can now be deployed to the 
seabed, and the hydraulic damper will ensure a 
smooth sample taking to avoid a shock wave 
during penetration. 
 
When hoisting the sampler the sediment tubes 
will be withdrawn from the sediment, and the 
lids will close to protect the samples from exit. 
 

 

Summary of Contents for 71.500

Page 1: ...KC Multi corer 4 x 100 mm Model 71 500 Manual KC Denmark Research Equipment Limnology Oceanography Hydrobiology...

Page 2: ...6 9 11 Attaching the sample tubes 6 7 12 Lead weights 8 13 16 Adjustable penetration depth 8 9 17 Extending the corers footprint 9 18 The hydraulic damper 10 19 20 Deploying the multi corer 10 21 23 S...

Page 3: ...must be released only when the multi corer is outside the rail of the boat Except for item 5 water filling of hydraulic damper KC Denmark A S is not and cannot be held responsible for any damage s ma...

Page 4: ...mes with only one safety clamp Attach the safety clamp at the top of the corer ensuring the handle is locked properly at 1 The photo shows an old model with 2 safety clamps 2 Push up the lid The wire...

Page 5: ...ools as the unit must glide over the bar during release of the sampler 4 It is very important to attach the snap hook at F Attaching at G will cause malfunction to the lid 5 The handle behind the lid...

Page 6: ...l wire is inserted into J so the bottom lid is locked in open position When loaded you must avoid an unattended release as the mechanism may cause injury to people 7 Open the quick release bracket for...

Page 7: ...reinforcement at the top 10 The reinforcement of the tube is aligned at the quick release Check if the lower end of the tube is inserted correct item 8 11 Tighten the handle to secure the tube Do not...

Page 8: ...weights Adjustable penetration depth 13 Before mounting the bracket for adjustable penetration depth optional you must ensure that the security clamp is placed correctly see item 1 14 The bracket is a...

Page 9: ...tration move the bracket in vertical position and fasten by means of the 4 bolts 16 Extending the corers footprint 17 Four extension legs optional can be added for better stability in strong currents...

Page 10: ...or deployment When the rack is outside the bulwarks you can remove the safety clamps 1 The photo shows an old model with 2 safety clamps If you must remove the security clamp while the sampler is on d...

Page 11: ...ejecting the sample 22 For emptying the sample tube you must hold a thin plate at the end of the tube to keep the sample while removing the tube 23 The sample ejection aggregate is optional 1 The sam...

Page 12: ...ts must be rinsed carefully with fresh water to avoid rust and corrosion You can store the sampler in two ways 1 In loaded position having both safety clamps attached 2 You may remove the safety clamp...

Page 13: ...to the weight station at the top of the rack When you raise the sampler it is important to have a reasonable weight on the rack to ensure the closing mechanism will work correctly If the weight of th...

Reviews: