Digital Pressure Sensor Switch 

Output Operation Mode

 This product has 4 output operation modes (Mode 0~3) and an analog output mode. Use suitable mode in accordance to work. For more details about 

output operation mode, refer to the graph below.

 If the output mode is set to 0, there will have no output except the display of the applied pressure (Used as a pressure gauge)

 Output wire classification

    - Black wire : Control output 1 according to P-H/P-L setting value and output mode.

                       OUT1/ OUT2 LED will be ON

    - White wire : Control output 2 according to P-H/P-L setting value and output mode.

                      OUT1/OUT2 LED will be ON

    - Gray wire : Analog output

Pressure Output Mode 0

No Output

Using as pressure gauge

Pressure Output Mode 1

Pressure Output Mode 2

Pressure Output Mode 3

Analog Output

KTD-600 Mode (Compound Pressure)

Pressure

Mode

Pressure (Min.) ← Pressure (0) → Pressure (Max.)

Analog Mode 0

None

Analog Mode 1     1

±

0.1V       ←     1.4

±

0.1V      →       5

±

0.1V

Analog Mode 2     5

±

0.1V       ←     4.6

±

0.1V      →       1

±

0.1V

Analog Mode 3                               1

±

0.1V       →       5

±

0.1V

Analog Mode 4                               5

±

0.1V       →       1

±

0.1V

Analog Mode 5

    0+0.1V        ←      0.6

±

0.1V     →       5

±

0.1

Analog Mode 6     5

±

0.1V       ←      4.4

±

0.1V     →       0+0.1V

KTD-600V Mode (Negative Pressure)

Pressure

Mode

Pressure (0kPa)     →   Pressure (-100kPa)

Analog Mode 0

None

Analog Mode 1

1

±

0.1V         →         5

±

0.1V

Analog Mode 2

5

±

0.1V         →         1

±

0.1V

Analog Mode 3

0+0.1V          →         5

±

0.1V

Analog Mode 4

5

±

0.1V         →         0+0.1V

Reviews: