Quick Reference 
Guide

For Patient Use

Important Safety Information

accompanies this device.

Review with your doctor or nurse 

prior to use.

Indications, Contraindications, Warnings,

Precautions and other important

Safety Information are contained in the

V.A.C.

®

 Therapy Safety Information Sheet

which, along with this QRG, should always

be kept in the pocket inside the front fl ap

of the carrying case.

If there are questions, or if this information

is missing, immediately contact your

local KCI representative.

Patient Feature Identifi cation

Power Therapy Unit On or Off

Press and hold the 

Power On/Off

 button 

for approximately two seconds to turn 
the ActiV.A.C.

®

 Therapy Unit on or off.

Therapy On or Off

Start or stop V.A.C.

®

 Therapy.

A lighted green crescent means V.A.C.

®

 

Therapy is on.

Audio Pause

Press 

Audio Pause

 to silence (for 60 

minutes) alerts that do not need 
immediate attention.  

Alarms needing immediate attention 
override the Audio Pause feature.

Battery Charging

Indicator Light

ActiV.A.C.

®

Canister

 Power  On/Off 

Button

Touch

Screen

Power

Connection

On/Off

On/Off

Audio Pause

Patient Mode Home Screen

Carrying Case Options

The ActiV.A.C.

®

 carrying case has an integrated belt 

loop and a separate adjustable strap to allow for 
versatile carrying options.

Keep the ActiV.A.C.

®

 Therapy Unit in 

the upright position. The touch screen 
should be in a readable, right-side-
up orientation or facing up when the 
therapy unit is laid on a level surface.

Continuous
Therapy Off 
0mmHg

Patient Mode

Jul 19 2009

18:06

58:23

Audio Pause

On/Off

Mode Indicator 

Current Date 

Current Time

Therapy 

Status Bar 

and Display 

Area

Screen

Guard

This icon rotates 

when the ActiV.A.C.

®

 

Therapy Unit is 

applying negative 

pressure.

Battery Level

Indicator

Help

Button

Therapy

On/Off

Button

Audio Pause 

Indicator with 

Countdown Timer

Alerts and Alarms

See the Alerts and Alarms section of the 
ActiV.A.C.

®

 Therapy System User Manual 

for more details. If necessary, contact your 
doctor or nurse or KCI for assistance or further 
information.

Alerts

Alerts will be displayed on the touch screen when 
the ActiV.A.C.

®

 Therapy Unit detects a condition 

that requires patient or caregiver attention. A single 
audible tone will sound.

•  Battery Low Alert: About two hours of battery 

power remain. Recharge the battery.

•  Blockage Alert: Check tubing for closed clamps, 

kinks, crimps and blockages. Lower therapy unit 
and tubing to or below the wound level.

•  Low Pressure Alert: Check tubing for closed 

clamps, kinks, crimps and blockages. Lower 
therapy unit and tubing to or below the wound 
level.

•  Service Timer Expired Alert: Contact KCI for 

instructions.

Alarms

Alarms will be displayed on the touch screen when 
the ActiV.A.C.

®

 Therapy Unit detects a condition 

that 

requires immediate patient or caregiver 

attention.

 Repeating audible tones will sound.

Press to silence the audible tone for two 
minutes.

•  Battery Critical Alarm: About 30 minutes of 

battery power remain. 

Immediately recharge 

the battery.

•  Blockage Alarm Therapy Interrupted: Check 

tubing for closed clamps, kinks, crimps and 
blockages. Lower therapy unit and tubing to or 
below the wound level.

•  Canister Full Alarm: Change canister and restart 

therapy.

•  Canister Not Engaged Alarm: Ensure canister is 

properly installed.

•  Leak Alarm: Use leak detection procedures and 

the 

Seal Check™

 Leak Detector to help fi nd and 

repair leak.

•  Leak Alarm Therapy Interrupted: A leak has been 

detected and not resolved. Press 

Reset

 and restart 

therapy.

•  Low Pressure Alarm Therapy Interrupted: Check 

tubing for closed clamps, kinks, crimps and 
blockages. Lower therapy unit and tubing to or 
below the wound level.

•  System Error Alarm: A technical fault has 

occurred. Turn unit off and then back on. If the 
fault persists, contact KCI.

•  Therapy Inactive Alarm: Therapy has been off for 

15 minutes. Restart therapy.

Press 

Help

 for more information.

Press 

Help

 for more information.

Audio Pause

KCI USA, INC. 

KCI Medical Products (UK), Ltd.

San Antonio, Texas 

Wimborne, Dorset 

78219 USA 

BH21 7SH 

1-800-275-4524 

United Kingdom 

www.kci1.com www.kci-medical.com

Questions and Information

For medical questions, please consult your 
doctor or nurse. In case of medical emergency, 
immediately contact your local emergency 
services provider.

This Quick Reference Guide is not intended to be a 
comprehensive manual. For additional information 
concerning the ActiV.A.C.

®

 Therapy System, 

including detailed operating instructions, please 
consult the ActiV.A.C.

®

 Therapy System User Manual 

and your doctor, nurse, caregiver or KCI.

Customer Contact Information

For questions regarding this product, supplies, 
maintenance, or additional information about KCI 
products and services, please contact KCI or a KCI 
authorized representative, or:

In the US

 call 1-800-275-4524 or visit www.kci1.

com.

Outside the US 

visit www.kci-medical.com.

All trademarks designated herein are property of KCI 
Licensing, Inc., its affi liates, and licensors. 
©2011 KCI Licensing, Inc. All Rights Reserved.  