background image

1

INTRODUCTION

GENERAL

Keating MIRACLEAN® Electric Griddles are designed

to give maximum production efficiency, delivering high

quality food products. The following design features are

incorporated into Keating MIRACLEAN® Electric

Griddles.

STANDARD

FEATURES

l

MIRACLEAN® energy efficient plate

l

Welded stainless steel perimeter

l

Welded stainless steel grease trough

l

Baffle grease drawer with rear handle

l

Stainless steel control panel

STANDARD

ACCESSORIES

l

Keating griddle scraper

l

Package of 10 scraper blades

l

Palmetto brush

l

Keating trough scraper

l

4” special Keating spatula

l

Keating egg turner

l

Keating Klenzer sample

OPTIONS

l

380 or 480 volt input

l

Single phase input

l

High input heating elements

MODEL VARIATION

Standard Griddles: Keating MIRACLEAN® electric

griddles are available in widths ranging from 27” to

72” and in 24”, 30” and 33” depths. The electric

griddles are UL, CGA and NSF listed.

SAFETY PRECAUTIONS

WARNING

THIS SYMBOL WARNS YOU THAT SERIOUS BURNS

OR OTHER INJURIES MAY RESULT IF SAFETY

INSTRUCTIONS ARE NOT FOLLOWED.

l

This service manual should be retained in a safe

place for future reference.

l

The installation of your new griddle must conform to

local codes or in the absence of local codes, with the

current National Electrical Code ANSI/NFPA 70 or

Canadian Electrical Code CAN 22.2 as applicable.

l

Your ventilation hood, when installed, must conform

to the current ANSI/NFPA 96 standard.

l

Installation clearance requires 6” from rear and side

walls.

l

You must maintain this appliance free and clear from

combustibles.

l

Adequate clearance for servicing and proper

operation must be maintained.

l

Your Keating MIRACLEAN® is designed to be

serviced form the front, except for the rear field wire

connections (electric input).

l

Keating commercial griddles are intended for other

than household use.

l

ALWAYS instruct new employees on proper griddle

operation.

l

A MIRACLEAN® griddle should be operated ONLY

by properly trained personnel.

l

ALWAYS turn griddle off each night.

l

ALWAYS disconnect electrical supply before

servicing.

l

NEVER leave a griddle unattended during operation.

l

NEVER move griddle when hot.

THIS GRIDDLE MAY NOT BE ALTERED, MODIFIED

OR CHANGED IN ANYWAY.
Safe operation of this equipment is

possible only when the operating

instructions and the safety

precautions are read completely

and the instructions contained

therein are strictly observed. Before

operating this equipment, ask for a

practical demonstration.
Periodically inspect cable and plug,

if provided, before using machine.

Servicing should be performed by

qualified and licensed service

companies.

Summary of Contents for MIRACLEAN

Page 1: ...MIRACLEAN ELECTRIC GRIDDLE SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com...

Page 2: ...Warranty Repairs 5 Preventive Maintenance 5 Griddle Surface 6 Cleaning 6 Limited Calibration 6 SECTION V SERVICE DIAGNOSIS General 7 Trouble Shooting Chart 7 SECTION VI PARTS LIST Ordering Parts 8 War...

Page 3: ...OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS O...

Page 4: ...he absence of local codes with the current National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CAN 22 2 as applicable l Your ventilation hood when installed must conform to the current A...

Page 5: ...ONING The griddle must be placed under an exhaust hood with a fire retardant system Your ventilation hood when installed must conform to the current ANSI NFPA 96 standard ALL connections and placement...

Page 6: ...system refer to the Electric Griddle Specifications on pages 14 to 16 to determine the full load rating of the griddle NOTE A hole has been punched in the rear of the griddle cabinet for a cord or con...

Page 7: ...of elements under MIRACLEAN plate for 27 or 30 wide griddles 5 After each load scrape the griddle surface completely clean using the 4 wide replaceable blade scraper CAUTION DO NOT HACK CHOP HIT OR CU...

Page 8: ...TDOWN 1 Turn each thermostat fully counterclockwise and On Off switch of OFF position IV MAINTENANCE WARRANTY REPAIRS Keating s warranty begins with the date of installation In the event that your MIR...

Page 9: ...griddle Figure 4 1 Thermostat calibration with knob on 4 If calibration of griddle is found to be less than 15 F off simply loosen three dial plate retaining screws See Figure 4 1 rotate dial plate to...

Page 10: ...faulty d Replace On Off switch e Thermostat isn t on e Turn thermostat to desired cooking temperature f Thermostat is faulty f Replace thermostat g Connections are loose g Tighten connections h Eleme...

Page 11: ...Keating MIRACLEAN Electric Griddle should be in place at all times If plates are damaged or lost replace them immediately Figure 6 1 MIRACLEAN Electric Griddle Assembly ITEM DESCRIPTION PART NUMBER 1...

Page 12: ...550 F BLACK 009914 035950 2 THERMOSTAT DIAL PLATE 250 400 F 034870 THERMOSTAT DIAL PLATE 150 500 F 012018 3 THERMOSTAT 245 400 F 208 240 VOLT 035954 THERMOSTAT 150 550 F 208 240 VOLT 029521 4 ON OFF...

Page 13: ...002480 1 2 HEATING ELEMENT PAN 020553 1 020554 020555 1 020556 1 3 INSULATION BOARD 002489 1 002493 1 002490 1 4 HEAT DISPERSION PLATE 005913 1 006228 1 006229 1 5 HEATING ELEMENT BULB 1 1 1 HOLD DOWN...

Page 14: ...ype D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles The following wiring diagrams are for griddles rated at 208 240 volts which have separat...

Page 15: ...12 36 AND 42 48 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 36 WIDE 42 48 WIDE...

Page 16: ...13 60 AND 72 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 60 WIDE 72 WIDE...

Page 17: ...6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 AMPS PER LINE THREE PHASE l 3 ELEMENTS 2300 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 3 26 34 26 50 220 11 5 28 36 28 52 240 13 7 30...

Page 18: ...TS kW SINGLE L1 L2 L3 PHASE 208 13 4 34 45 34 64 220 15 0 36 47 36 68 240 17 9 39 52 39 75 AMPS PER LINE THREE PHASE l 5 ELEMENTS 3000 W EACH 60x30 A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 7 34 3...

Page 19: ...CH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 13 4 43 43 28 64 220 15 0 45 45 30 68 240 17 9 49 49 32 75 AMPS PER LINE THREE PHASE l 4 ELEMENTS 3750 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 2...

Page 20: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Page 21: ...____________________________________ ADDRESS ______________________________________________________________________________________________________________ CITY _______________________________________...

Reviews: