ELECTRICAL

CONNECTION

The Keating Electric MIRACLEAN® Griddle is

equipped with a three wire terminal block for customer

connections. Compare the griddle terminal connections

to the appropriate wiring diagram for the griddle (see

pages 11 and12 - Wiring Diagrams) to see if the griddle

is connected three phase or single phase. All wires,

cords, plugs, receptacles and circuit breakers must be

sized adequately for the full load rating of the griddle as

specified by local codes or, in the absence of local

codes, by the current National Electrical Code

ANSI/NFPA 70 or the Canadian Electrical Code CAN

22.2 as applicable.
The Electric MIRACLEAN® Griddle is also equipped

with a grounding lug next to the terminal block. For

proper grounding procedures, see local codes or, in the

absence of local codes, the current National Electrical

Code ANSI/NFPA 70 or the Canadian Electrical Code

CAN 22.2 as applicable.

NOTE: 

The connections to the griddle can be changed

in the field from three phase to single phase or from

single phase to three phase. This can be done by

simply changing the wiring at the terminal block. To

change the connections for your griddle, see the

appropriate wiring diagram for your griddle on pages 11

and 12.

NOTE: 

For griddles rated at 208-240 volts, the

amperage ratings marked on the nameplates of the

griddles are listed at 240 volts as required by UL. If

your griddle uses a 208 or 220 volt system, refer to the

Electric Griddle Specifications on pages 14 to 16 to

determine the full load rating of the griddle.

NOTE: 

A hole has been punched in the rear of the

griddle cabinet for a cord or conduit exit. If a cord is

used, the National Electrical Code, UL standards and

most local codes require a bushing or strain relief (not

provided by Keating) to protect the cord.

III OPERATING

CONDITIONING THE

GRIDDLE 

The MIRACLEAN® Griddle plate has been “seasoned”

at the factory. The chrome surface when heated

creates a thin layer of chrome oxide which acts as a

releasing agent for food products. If you feel you need

to recondition the surface, the following instructions

should be followed:
1.  Follow cleaning instructions on page 6.
2.  Heat the MIRACLEAN® to 400°F for one hour.
3. Lower thermostat to 350°F, allowing the

MIRACLEAN® to cool to about 350°F, as is evident

when griddle cycles on or surface thermometer

indicates correct temperature.

4.  Lightly coat the MIRACLEAN® surface with griddle

oil.

NOTE: 

Despite the food releasing properties, the

chrome surface is not a true “non-stick” surface. For

best cooking results and product appearance, use

griddle oil for products that require the surface to be

conditioned.

COOKING

Keating MIRACLEAN® Griddles are designed to

provide maximum production efficiency and deliver

high quality food products. Follow cooking procedures

below.
1.  Set ON/OFF switch to “ON” position. The Power

indicating light will illuminate.

2.  Set the thermostat to the desired temperature and

wait ten minutes for  preheating. Recommended

cooking temperatures for various food products are

as follows:

Summary of Contents for MIRACLEAN

Page 1: ...MIRACLEAN ELECTRIC GRIDDLE SERVICE MANUAL KEEP THIS MANUAL FOR TRAINING NEW PERSONNEL 1 800 KEATING www keatingofchicago com...

Page 2: ...Warranty Repairs 5 Preventive Maintenance 5 Griddle Surface 6 Cleaning 6 Limited Calibration 6 SECTION V SERVICE DIAGNOSIS General 7 Trouble Shooting Chart 7 SECTION VI PARTS LIST Ordering Parts 8 War...

Page 3: ...OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS O...

Page 4: ...he absence of local codes with the current National Electrical Code ANSI NFPA 70 or Canadian Electrical Code CAN 22 2 as applicable l Your ventilation hood when installed must conform to the current A...

Page 5: ...ONING The griddle must be placed under an exhaust hood with a fire retardant system Your ventilation hood when installed must conform to the current ANSI NFPA 96 standard ALL connections and placement...

Page 6: ...system refer to the Electric Griddle Specifications on pages 14 to 16 to determine the full load rating of the griddle NOTE A hole has been punched in the rear of the griddle cabinet for a cord or con...

Page 7: ...of elements under MIRACLEAN plate for 27 or 30 wide griddles 5 After each load scrape the griddle surface completely clean using the 4 wide replaceable blade scraper CAUTION DO NOT HACK CHOP HIT OR CU...

Page 8: ...TDOWN 1 Turn each thermostat fully counterclockwise and On Off switch of OFF position IV MAINTENANCE WARRANTY REPAIRS Keating s warranty begins with the date of installation In the event that your MIR...

Page 9: ...griddle Figure 4 1 Thermostat calibration with knob on 4 If calibration of griddle is found to be less than 15 F off simply loosen three dial plate retaining screws See Figure 4 1 rotate dial plate to...

Page 10: ...faulty d Replace On Off switch e Thermostat isn t on e Turn thermostat to desired cooking temperature f Thermostat is faulty f Replace thermostat g Connections are loose g Tighten connections h Eleme...

Page 11: ...Keating MIRACLEAN Electric Griddle should be in place at all times If plates are damaged or lost replace them immediately Figure 6 1 MIRACLEAN Electric Griddle Assembly ITEM DESCRIPTION PART NUMBER 1...

Page 12: ...550 F BLACK 009914 035950 2 THERMOSTAT DIAL PLATE 250 400 F 034870 THERMOSTAT DIAL PLATE 150 500 F 012018 3 THERMOSTAT 245 400 F 208 240 VOLT 035954 THERMOSTAT 150 550 F 208 240 VOLT 029521 4 ON OFF...

Page 13: ...002480 1 2 HEATING ELEMENT PAN 020553 1 020554 020555 1 020556 1 3 INSULATION BOARD 002489 1 002493 1 002490 1 4 HEAT DISPERSION PLATE 005913 1 006228 1 006229 1 5 HEATING ELEMENT BULB 1 1 1 HOLD DOWN...

Page 14: ...ype D 1 thermostats which include On Off switches Separate On Off switches are not provided with these griddles The following wiring diagrams are for griddles rated at 208 240 volts which have separat...

Page 15: ...12 36 AND 42 48 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 36 WIDE 42 48 WIDE...

Page 16: ...13 60 AND 72 WIDE ELECTRIC GRIDDLE WIRING DIAGRAM 60 WIDE 72 WIDE...

Page 17: ...6 2 17 17 17 30 220 6 9 18 18 18 31 240 8 2 20 20 20 34 AMPS PER LINE THREE PHASE l 3 ELEMENTS 2300 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 3 26 34 26 50 220 11 5 28 36 28 52 240 13 7 30...

Page 18: ...TS kW SINGLE L1 L2 L3 PHASE 208 13 4 34 45 34 64 220 15 0 36 47 36 68 240 17 9 39 52 39 75 AMPS PER LINE THREE PHASE l 5 ELEMENTS 3000 W EACH 60x30 A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 10 7 34 3...

Page 19: ...CH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 13 4 43 43 28 64 220 15 0 45 45 30 68 240 17 9 49 49 32 75 AMPS PER LINE THREE PHASE l 4 ELEMENTS 3750 W EACH A M P S VOLTS kW SINGLE L1 L2 L3 PHASE 208 2...

Page 20: ...PARTICULAR PURPOSE OR WARRANTY AGAINST LATENT DEFECTS E XCLUSIONS The warranties provided by Keating of Chicago Inc do not apply in the following instances 1 Defects arising out of or resulting from...

Page 21: ...____________________________________ ADDRESS ______________________________________________________________________________________________________________ CITY _______________________________________...

Reviews: