background image

2

Servicing should be performed by qualified and
licensed service companies.

This unit is designed to be connected by fixed wiring
only. Cords and plug caps are not acceptable.
Electrical connection must be hard-wired by qualified
personnel.

This is a fixed appliance and requires a disconnect on
the fixed wiring with a contact separation of at least
(3mm) in all poles. Power connection must remain
accessible after installation.

NOTE: 

Only install in a non-combustible supporting

surface.

II INSTALLATION

This unit must be installed, inspected, calibrated and
serviced by qualified and/or certified and licensed
personnel. Contact your dealer for assistance.

INSTALLATION

Installation must conform with local codes.

DAMAGE DURING SHIPMENT

The griddle has been assembled, tested and inspected
at the factory. Upon arrival, the complete griddle should
be checked for any damage that may have occurred
during shipment.

What to do if equipment arrives damaged:

VISIBLE LOSS OR DAMAGE – Be certain to note this
on the freight or express receipt and have it signed by
the delivery person.

POSITIONING

The griddle must be placed under an exhaust hood
with a fire retardant system. ALL connections and
placements must comply with local and national codes.
It is the responsibility of the owner and local installer to
comply with these regulations when installing the
griddle. 

LEVELING

Your Teppanyaki Griddle will operate at its highest
efficiency when properly leveled. The Teppanyaki
griddle must be leveled within the table and the table
must be leveled to the floor.

ELECTRICAL
CONNECTION

The Teppanyaki Griddle is equipped with a three wire
terminal block with ground for field wiring. Compare the
griddle terminal connections with the wiring diagram on

page 7. This unit is designed to be connected by hard
fixed wiring only. Cords and plug caps are not
acceptable. Electrical connection must be hard-wired
by qualified personnel.

THIS APPLIANCE MUST BE EARTHED.

NOTE: NOT FOR OUTDOOR INSTALLATION.

NOTE:

Customer must provide drawing of table that

will be used, and table must be ventilated. Keating
does not manufacture the table.

III OPERATING

CONDITIONING THE
MIRACLEAN

®

GRIDDLE 

The Teppanyaki Griddle plate has been “seasoned” at
the factory. The chrome surface when heated creates a
thin layer of chrome oxide which acts as a releasing
agent for food products. If you feel you need to
recondition the surface, the following instructions
should be followed:

1.  Follow cleaning instructions on page 3.

2.  Heat the Teppanyaki to 400°F (204°C) for one

hour.

3.  Lower thermostat to 350°F (177°C), allowing the

Teppanyaki to cool to about 350°F (177°C), as is
evident when griddle cycles on or surface
thermometer indicates desired temperature.

4.  Lightly coat the Teppanyaki surface with griddle oil.

NOTE:

Despite its food releasing properties, the

chrome surface is not a true “non-stick” surface. For
best cooking results and product appearance, use
griddle oil for products that require the surface to be
conditioned.

CONDITIONING THE
POLISHED STEEL
GRIDDLE

The surface of the polished steel griddle is conditioned
by lightly coating the surface with griddle oil before
each run of product.

COOKING

Follow cooking procedures below.

1.  The actual heating section on all Teppanyaki

griddles is 24"(610mm)x18"(457mm). The heating
section is located in the center front of the griddle.

WARNIN

G

Summary of Contents for MIRACLEAN

Page 1: ... AND OPERATING PLATES 6 TEPPANYAKI ELECTRIC GRIDDLE CONTROL PANEL 6 HEATING ELEMENT ASSEMBLY 7 SECTION VII WIRING DIAGRAMS TEPPANYAKI GRIDDLE 7 CONTENTS IMPORTANT Keep a copy of your bill of sale The date on the bill establishes the warranty period should service be required If service is performed it is in your interest to obtain and keep all receipts Keating commercial griddles are not intended ...

Page 2: ...ge specifications at any time B WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THESE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WA...

Page 3: ...ace for future reference The installation of your new griddle must conform to local codes Your ventilation hood when installed must conform to the current standard Installation clearance requires 6 152mm from rear and side walls and supporting surfaces regardless of size of unit 6 152 4mm side clearance also required below the cooking surface Adequate clearance for servicing and proper operation m...

Page 4: ...N The Teppanyaki Griddle is equipped with a three wire terminal block with ground for field wiring Compare the griddle terminal connections with the wiring diagram on page 7 This unit is designed to be connected by hard fixed wiring only Cords and plug caps are not acceptable Electrical connection must be hard wired by qualified personnel THIS APPLIANCE MUST BE EARTHED NOTE NOT FOR OUTDOOR INSTALL...

Page 5: ...ent of elements under Teppanyaki Griddle plate 4 After each load scrape the griddle surface completely clean using the 4 102mm wide replaceable blade scraper DO NOT HACK CHOP HIT OR CUT ON THE TEPPANYAKI SURFACE You will dent the steel plate under the trivalent chrome It is even possible to hack two nicks close together and actually tear the Teppanyaki surface as the chromium will not stretch Belo...

Page 6: ...vicing will lead to years of quality performance CALIBRATION Tools Accurate surface thermometer Standard screwdriver 1 Turn on the griddle with thermostat set at 300 F 149 C Allow elements to cycle on and off three times Approximately 10 minutes 2 Place thermometer on surface over thermostat bulb The thermostat bulb is approximately 2 3 to 3 4 of the way straight back to the rear of the griddle 3 ...

Page 7: ...a qualified service company PROBLEM PROBABLE CAUSE SOLUTION Griddle won t heat a No electricity to griddle a Connect griddle to an approved source of power b Thermostat isn t on b Turn thermostat to desired cooking temperature c Thermostat is faulty c Replace thermostat d Connections are loose d Tighten connections e Element is faulty e Replace element Temperature of griddle a Thermostat out of ca...

Page 8: ...NG or your service company You may also order online at Keating s part store www keatingofchicago com The model serial plate is located on the control panel assembly The serial and model numbers are necessary when ordering WARNING AND OPERATING PLATES All warning and operating plates on the Keating Teppanyaki Electric Griddle should be in place at all times If plates are damaged or lost replace th...

Page 9: ... 3 INSULATION BOARD 24 610mm 002489 4 HEATING ELEMENT PAN 24 610mm 020553 5 HEATING ELEMENT BULB HOLD DOWN M BRACKET 008593 6 HEATING ELEMENT HOLD DOWN BRACKET 029352 7 3 8 9 525mm NUT WASHER LOCK WASHER AND PALNUT 028736 Items 6 7 as a kit 029352 HEATING ELEMENT ASSEMBLY VII WIRING DIAGRAM A wiring diagram is mounted inside the control panel of every griddle See your individual piece of equipment...

Page 10: ...08 10 ...

Page 11: ...________________________________________________ ADDRESS __________________________________________________________________________________________________________________ CITY ______________________________________________________________________________ STATE ________________ ZIP ____________ DEALER _________________________________________________________________________________________________...

Reviews: