12
PROBLEM
PROBABLE CAUSE
SOLUTION
Burner light does not
l
Check for spark at each burner.
come on.
If no spark at either burner:
a. Purge time delay relay is faulty
a. Replace purge time delay relay.
(if it has no output voltage.)
b. Spark module is faulty.
b. Replace spark module.
l
Check for spark at each burner.
If spark occurs at both burners:
c. Burner light is faulty.
c. Replace burner light.
Burner light comes on,
l
Check for spark at each burner.
then goes out (after 2-1/2
If no spark at either burner:
seconds.)
a. Spark electrode wires are faulty.
a. Replace or tighten spark electrode wires.
b. Spark electrode is faulty or is
b. See detail on page 19.
out of alignment.
l
Check for spark at each burner.
If spark occurs at both burners:
c. Gas is not turned on.
c. Turn manual gas valve on. If using
flexible connector with quick
d. Spark electrode is faulty or is
disconnect, make sure that the quick
out of alignment.
disconnect is completely engaged.
d. Align spark electrode. Replace
spark electrode if faulty. Gap must be
1/8" between electrode and pilot tube
and between pilot tube & burner.
(See page 19)
e. Combination gas valve is faulty.
e. Replace combination gas valve after
verifying it has voltage.
Delayed ignition.
a. Spark electrode gap is incorrect.
b. Set proper gap on electrode. (See
detail on page 19)
b. Gas pressure excessive
c. Set pressure to serial plate.
(incoming or manifold).
c. Spark module intermittent.
d. Replace spark module.
Fryer has poor recovery.
a. Over-filling baskets.
a. Don’t over-fill baskets.
b. Over-filling fryer with oil.
b. Fill fryer up to “Fill Level” line as oil will
expand when heated.
c. Thermostat bulb improperly
c. Adjust bulb position. See page 9 –
placed.
Thermostat Bulb Positioning.
d. Carbon coating on heat transfer
d. Boil-out fryer. See page 7 –
tubes.
Cleaning and Boil-out.
e. Low gas pressure or volume.
e. Contact a qualified service person to
check gas pressure.
f. Inefficient burner combustion.
f.
Adjust gas/air mixture. See page 10
– Flame Adjustment.
Fryer overshoots
a. Thermostat bulb improperly
a. Adjust bulb position. See page 9 –
temperature setting.
placed.
Thermostat Bulb Positioning.
b. Thermostat out of calibration.
b. Calibrate thermostat. See page 9 –
Calibration.