THE CONNECTOR, AS SPECIFIED IN THE
APPLIANCE MANUFACTURER’S INSTRUCTIONS.

INSTALLATION

The installer is responsible for attaching the tipping
restraint.

ELECTRICAL CONNECTION

The Keating IFM, when installed, must be electrically
grounded in accordance with local codes, or in the
absence of local codes, the National Electrical Code,
ANSI/NFPA No. 70. or the Canadian Electrical Code,
CSAC-22.2 as applicable. A wiring diagram is located on
the last page. In the U.S.A. and Canada, the electrical
supply must be 120 VAC, 60 Hz.

The Keating Incredible Frying Machine (IFM) is
equipped with a 9' neoprene covered, 3 wire electrical
cord with a three-pronged grounded plug for protection
against electrical shock. This plug must be placed into
a 120V properly grounded three-pronged polarized
outlet. For proper grounding procedures see local
codes, or in the absence of local codes, the National
Electrical Code ANSI/NFPA 70 (latest edition) or
Canadian Electrical Code CAN 22.2 (latest edition) as
applicable.

CAUTION

Before plugging in the fryer, confirm the outlet is
properly polarized and grounded. If the hot and neutral
terminals are reversed or the outlet is not properly
grounded, the burners may not ignite (burner on light
will go out after 2-1/2 seconds and the ignition
processes will continue 3 times).

WARNING

THIS APPLIANCE IS EQUIPPED WITH A THREE-
PRONG 120 VOLT NEMA 5-15 (GROUNDING) PLUG
FOR YOUR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED DIRECTLY
INTO A PROPERLY GROUNDED AND POLARIZED
THREE-PRONG RECEPTACLE. DO NOT CUT OR
REMOVE THE GROUNDING PRONG FROM THIS
PLUG. (MODEL AA HAS NO ELECTRIC
CONNECTION).

WARNING

IF DISCONNECTION OF THE RESTRAINT IS
NECESSARY, IT MUST BE RECONNECTED WHEN
THE FRYER IS RETURNED TO ITS ORIGINALLY
INSTALLED POSITION.

GAS CONNECTION

WARNING

• PIPE JOINT COMPOUNDS RESISTANT TO

PROPANE GASES MUST BE USED.

• BEFORE OPERATING THIS FRYER, CHECK PIPE

JOINTS FOR LEAKS BY USING A SOAP AND
WATER SOLUTION ONLY. DO NOT USE AN OPEN
FLAME!

Figure 2-3

Main Gas Connection

Connect the fryer to the main gas supply line at the rear
of the fryer. The piping should be a minimum of 3/4"
NPT supply pipe for a single fryer at the burner
manifold. Batteries require larger supply lines.
Installation must conform to the current local codes and
National Fuel Gas Code (U.S.) ANSI Z223. 1/NFPA 54
(latest edition), Natural Gas Installation Code
CAN/CGA-B149.1 or Propane Installation Code
CAN/CGA-B149.2 (latest edition).

NOTE:

If more than one gas fryer is on the same supply

line, you may require a larger line. Consult your local gas
company to assure adequate volume and pressure.
Refer to serial plate for proper gas requirements for your
particular model.

NOTE:

Piping for a battery should be at least 1-1/4" to

1-1/2" IPS, depending on total BTU input. Consult your
local gas supplier for appropriate battery piping size.

NOTE:

The electrical wiring diagram for the fryer is

located on the inside of the fryer door or in the back of
this manual.

GAS LEAK TESTING

Prior to lighting your fryer:

1.

Make sure all thermostats, switches and safety
valves are in the “OFF” position.

2.

Turn main On/Off manual gas valve to the “ON”
position.

Summary of Contents for SERIES 2000

Page 1: ...anual del Usuario sirvase escribir la direcci n que se incluye a continuadi n SECTION IV MAINTENANCE Warranty Repairs 8 Preventive Maintenance 8 Oil Breakdown 8 Thermostat Calibration 8 Thermostat Bul...

Page 2: ...E GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE As continuous product improvement occurs specifications may be changed without notice IFM Model 2000 10 0...

Page 3: ...ble 120 VAC 9 neoprene cord with 3 pronged grounded plug Instant recovery to cooking temperature High temperature stainless steel flue lining 100 factory testing STANDARD ACCESSORIES Keating Klenzer S...

Page 4: ...for cooking THIS FRYER MAY NOT BE ALTERED MODIFIED OR CHANGED IN ANY WAY The State of California enacted the California Safe drinking water and Toxic Enforcement Act of 1986 Prop 65 which prohibits an...

Page 5: ...st be disconnected from gas supply piping system Counter model and floor model fryers must be restrained to prevent tipping when installed in order to avoid splashing spilling etc of hot liquid The re...

Page 6: ...ROPERLY GROUNDED AND POLARIZED THREE PRONG RECEPTACLE DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG MODEL AA HAS NO ELECTRIC CONNECTION WARNING IF DISCONNECTION OF THE RESTRAINT IS NECESSARY...

Page 7: ...IFM as they are not equipped with a melt cycle If solid shortening is used it should be melted prior to filling the fryer vessel Damage done by melting solid shortening in the fryer vessel will void...

Page 8: ...TS ON BASKET HANGERS OR ON FRYER VESSEL n CARE SHOULD BE TAKEN WHEN LOWERING BASKETS INTO FRYER TO PREVENT SPLASHING HOT OIL FROM FRYER VESSEL n NEVER LIFT BASKETS DIRECTLY OUT OF THE FRYER VESSEL WIT...

Page 9: ...UNATTENDED DURING BOIL OUT TRAINED PERSONNEL MUST BE PRESENT DURING THE PROCEDURE TO PREVENT BOIL OVER OR TO TURN OFF THE POWER IF WATER DROPS BELOW HEAT TRANSFER TUBES 6 Set thermostat and turn fryer...

Page 10: ...yearly intervals as necessary Following preventive maintenance procedures will help keep your fryer working efficiently Proper care and servicing will lead to years of quality performance A Oil Break...

Page 11: ...oduct n If the bulb is too tight the paper will either not pull through or it will tear A fryer with a thermostat bulb that is too tight will short cycle Short Cycle The thermostat will cycle rapidly...

Page 12: ...burner tube too much gas orange haze around burner tube showing incomplete combustion too little gas blue at front of burner or totally blue Remove the cover by loosening the screws to gain access to...

Page 13: ...come on Must be properly grounded b Breaker has tripped b Reset the breaker located on the bottom of the control panel c Main power switch is faulty c Replace the main power switch Blower light does...

Page 14: ...e if faulty Gap must be 1 8 between electrode and pilot tube and between pilot tube burner See page 19 e Combination gas valve is faulty e Replace combination gas valve after verifying it has voltage...

Page 15: ...ns are loose or b Make sure connections are tight electronic timer is faulty Replace timer if faulty c Motor limit switch is faulty c Replace limit switch or straighten arm d Lift motor is faulty d Re...

Page 16: ...DESCRIPTION QTY 1 030862 Blower 1 052471 Insulation 2 2 054162 Air Hose 2 015393 24 Clamp 2 3 Call 800 KEATING Fry Pot 1 4 020717 Pilot Tee 1 5 022031 Pilot Tubing 1 8 S S 2 6 016231 Elbow Brass 90 2...

Page 17: ...iew Side View 3 2 1 8 9 4 5 10 7 6 15 16 17 18 13 14 Burner Electrode Assembly See Detail on Page 19 12 11 Not Shown See page 17 18 for Control Panel Parts List INCREDIBLE FRYING MACHINE GAS FRYER SAF...

Page 18: ...16 INCREDIBLE FRYING MACHINE IFM GAS FRYER ASSEMBLY FRONT DRAIN II FOR REFERENCE ONLY HIGH LIMIT THERMOSTAT BURNER ASSEMBLY SEE PAGE 17 INSULATION...

Page 19: ...VAC 1 011505 12 6 Circuit Quick Connect Female 1 028301 Female Pins 6 028308 13 2 Circuit Quick Connect Female 1 032207 Female Pins 6 028308 14 Transformer 120V 24V 1 024032 15 4 Circuit Quick Connec...

Page 20: ...ect Female 1 028301 Female Pins 6 028308 13 2 Circuit Quick Connect Female 1 032207 Female Pins 6 028308 14 Transformer 120V 24V 1 024032 15 4 Circuit Quick Connect Female 1 032211 Female Pins 6 02830...

Page 21: ...S 5 6 2 SPARK ELECTRODE REPLACEMENT KIT 1 NATURAL GAS 052562 LP GAS 052908 3 OBSERVATION WINDOW ASSEMBLY LENS 016101 COVER 1 015905 4 BURNER OUTER PLATE ELBOW ASSEMBLY LEFT OR RIGHT SIDE 1 022158 5 BU...

Page 22: ...20 VIII WIRING DIAGRAMS 14 IFM 120V CONNECTION DIAGRAM NO TIMERS SAFE EASY READY CONTROL PANEL INSERT CONTROL PANEL BACK...

Page 23: ...21 CONTROL PANEL INSERT CONTROL PANEL BACK VIII WIRING DIAGRAMS 14 IFM 120V CONNECTION DIAGRAM TIMERS SAFE EASY READY...

Page 24: ......

Page 25: ...______________________________________________________________________________________ ADDRESS ______________________________________________________________________________________________________ CI...

Reviews: