BASIC SAfETy INSTrUCTIONS
• When using components without isolated inputs/outputs, it is necessary that equi-
potential bonding exists between the components to be connected (e.g. by the equi-
potential line). Disregard can cause destruction of the components by equalizing
currents.
1.4.1 EMC-compatible installation
Observance of the limit values required by EMC law is the responsibility of the manufac-
turer of the installation or machine.
Notes on EMC-compatible installation can be found here.
https://www.keb.de/fileadmin/media/Manuals/emv/0000neb0000.pdf
1.5 Start-up and operation
When the device is installed in machines, startup (i. e. the start of the intended use) is
prohibited until it is determined that the machine complies with the machine directive;
must be observed.
• During operation, all covers and doors shall be kept closed.
• Use only approved accessories for this device.
• Never touch terminals, busbars or cable ends.
1.6 Maintenance
The following maintenance work has to be carried out when required, but at least once
per year by authorized and trained personnel.
►
Check unit for loose screws and plugs and tighten if necessary.
► Clean devices from dirt and dust deposits. Pay attention especially to cooling fins
and protective grid of the fans.
► Examine and clean extracted air filter and cooling air filter of the control cabinet.
1.7 Preventive Maintenance
DANGEr
Unauthorized exchange, repair and modifications!
Unpredictable malfunctions!
►
The function of electronic devices can be affected by the setting and
parameterisation. Never replace without knowledge of the applica-
tion.
► Modification or repair is permitted only by
KEB Automation KG au-
thorized personnel.
►
Only use original manufacturer parts.
►
Infringement will annul the liability for resulting consequences.
Summary of Contents for C6 E22 BM-RVL
Page 1: ...EMBEDDED IPCS INSTRUCTIONS FOR USE E22 BOX PANEL Original Manual Document 20146638 EN 01 ...
Page 2: ......
Page 11: ...11 List of Figures Figure 89 External connectors 108 Figure 90 Buttons position detail 108 ...
Page 48: ...48 Installationand connection ...
Page 96: ...96 Drawings 7 1 4 C6 E22 PANEL SL S1 12 1 W Figure 75 12 1 Wide dimensions ...
Page 110: ...110 Certificatesandapprovals 8 Certificates and approvals 8 1 EU Declaration of conformity ...
Page 111: ...111 Certificatesandapprovals ...
Page 114: ......