INSTALLATION AND CONNECTION
3.9 Connecting C6 E22 BOX/PANEL
3.9.1 Notes on connection
• C6 E22 BOX/PANEL must be installed in accordance with the indications contained
in these operating instructions.
Follow the above instructions:
• Connect the system to the ground wire.
• Connect the power cable.
3.9.2 Grounding and bonding
Whenever two pieces of equipment connected to each other are far apart, it is possib-
le that their ground connections could be at a different potential level. The data cable
screens connecting the equipment’s chassis on one end and the C6 E22 BOX/PANEL
chassis on the other end can therefore be subject to a high current circulation capable
of destroying the interface. To overcome this hazard such current must be steered away
from the interface. To achieve this goal the following methods can be used:
Figure 46: Power supply diagramm - connection detail
1. Use an equipotential bonding cable (16mm
2
) to connect the equipment’ ground to
the C6 E22 BOX/PANEL ground.
2. Connect the data cable screens to the equipotential bonding rail on both sides befo-
re connecting the cable to the interfaces.
Summary of Contents for C6 E22 BM-RVL
Page 1: ...EMBEDDED IPCS INSTRUCTIONS FOR USE E22 BOX PANEL Original Manual Document 20146638 EN 01 ...
Page 2: ......
Page 11: ...11 List of Figures Figure 89 External connectors 108 Figure 90 Buttons position detail 108 ...
Page 48: ...48 Installationand connection ...
Page 96: ...96 Drawings 7 1 4 C6 E22 PANEL SL S1 12 1 W Figure 75 12 1 Wide dimensions ...
Page 110: ...110 Certificatesandapprovals 8 Certificates and approvals 8 1 EU Declaration of conformity ...
Page 111: ...111 Certificatesandapprovals ...
Page 114: ......