67
OPErATING SySTEMS
It is recommended to choose
“yes”
to ensure that no subsequent changes of the sys-
tem are committed accidentally, which could be happened if you quit the message box
with
“No”
.
If you choose
“Cancel”
the exit of the program is discarded and you can continue to
work in the KEB_WF_Mgr.
4.3 KEB Windows Embedded Standard 7 Image
4.3.1 Introduction
KEB has created a “Windows Embedded Standard 7 (WES7) image for C6 E22 with
special features that support you in the work with the device.
4.3.2 User Accounts
There are two user accounts implemented in the KEB WES7 image: AutoLogon and
remote. The following table shows the details for the accounts:
Account
AutoLogon
remote
Administrator
Yes
Yes
Password
remote
remote access
Not possible
Yes
Intention
Automatic logon after reboot
Remote Desktop connection
WArNING
The default password for “remote” account should be changed to
an individual password for security reasons!
Normally the AutoLogon should be continuously used as the standard logon because
only a logon without password reaches immediate start of Control and HMI application
after boot of the device, which is generally the desired behavior for a machine control
device. Because in WES7 a remote logon as an account without password is not possi-
ble there is no security risk regarding the missing password for AutoLogon.
Of course own user accounts can be created, but this is not the default approach des-
tined by KEB.
4.3.3 Ethernet Address
The C6 E22 is configured to get an IP address from a DHCP server. If no DHCP server
is available in the network the device uses the IP address 192.168.0.100. Thus it is also
possible to connect directly to the device without a network infrastructure with a deve-
lopment PC by configuring the Ethernet adapter of the development PC with another
192.168.0.xxx address.
Summary of Contents for C6 E22 BM-RVL
Page 1: ...EMBEDDED IPCS INSTRUCTIONS FOR USE E22 BOX PANEL Original Manual Document 20146638 EN 01 ...
Page 2: ......
Page 11: ...11 List of Figures Figure 89 External connectors 108 Figure 90 Buttons position detail 108 ...
Page 48: ...48 Installationand connection ...
Page 96: ...96 Drawings 7 1 4 C6 E22 PANEL SL S1 12 1 W Figure 75 12 1 Wide dimensions ...
Page 110: ...110 Certificatesandapprovals 8 Certificates and approvals 8 1 EU Declaration of conformity ...
Page 111: ...111 Certificatesandapprovals ...
Page 114: ......