63
Note
: To start the backup procedure the super capacitors must be fully charged.
Note
: The available retentive memory size is of 64KB for the RETAIN memory type
and 64KB for the PERSISTENT memory type.
Note
: If the power supply returns before the energy inside the Micro UPS is fin-
ished, and actually C6 HMI LC has not been switched off, the following operations
are carried on:
- The display is switched on
- The USB ports are powered
- CONTROL Runtime behavior can be selected in between 3 possible mod-
els:
a.
CONTROL Runtime does not start and no message is returned.
b.
CONTROL Runtime does not start and returns a warning message.
c.
CONTROL Runtime restarts normally (default option).