Product description | 3
ma_dr_f6-cu-a-inst-20118593_en
13
Control board
Safety module
Set contains
Material number
APPLICATION
Type 1
terminal strip 28-pole
terminal strip 20-pole
terminal strip 6-pole
00F6V80-001A
1)
APPLICATION
Type 3
terminal strip 32-pole
terminal strip 28-pole
terminal strip 6-pole
00F6V80-003A
1)
1)00F6V80-01xA customer-specific connector sets
Tab. 1:
Connector sets
3.4 Connection and control elements
X2A
NET ST
VCC
DEV ST
X2B
X4A
X4C
X4B
S1
S2
X3B
X3A
X1C
FS ST
OPT
X1C
Temperature monitoring, brake
control/ monitoring
X2A
Control terminal block for digital in-
puts/outputs; 24V supply; relay out-
put;analog inputs and outputs;CAN
bus
X2B
Safety module (variations depend-
ent)
X3A
Encoder interface channel A
X3B
Encoder interface channel B
X4A
Diagnostic interface with
RS232/485 interface according to
DIN 66019II protocol; operator slot
X4B
Realtime-Ethernet module (vari-
ations dependent)
X4C
Realtime-Ethernet module (vari-
ations dependent)
S1
Realtime-Ethernet module (vari-
ations dependent) Rotary coding
switch 1 (Low-Byte)
S2
Realtime-Ethernet module (vari-
ations dependent) Rotary coding
switch 2 (High-Byte)
FS ST
LED Safety state
VCC
LED voltage supply (24V)
NET ST LED network / fieldbus status
DEV ST LED Inverter / device status
OPT
optional
Tab. 2:
Overview Connection and control elements
3.5 Motor monitoring X1C (temperature, brake)
Terminal strip X1C is a 6-pole, pluggable terminal strip with spring-cage connection. It
contains:
• 1 output for control of 24V motor brakes
• 1 analog input for temperature detection