9 | Brake control and temperature detection
KEB Automation KG
34
ma_dr_f6-cu-a-inst-20118593_en
9 Brake control and temperature detection
X1C
PIN
Name
Notes
1
2
3
4
5
6
1
BR+
Brake control / output
2
BR-
Brake control / output
3
Reserved
4
Reserved
5
TA1
Temperature detection / input +
6
TA2
Temperature detection / input -
Tab. 15:
Assignment of the terminal block X1C
9.1 Brake control
VORSICHT
Wrong dimensioning of the brake
Brake does not release or only with delay
a) Choose the input voltage tolerance of the brake corresponding to the tolerance
of the output voltage.
b) Use auxiliary relays if necessary.
Specification brake/relay output
Name
BR+ (X1C.1); BR- (X1C.2)
Function
Output to supply a brake or relay.
Output voltage (DC)
minimum P24Vin – 2.4V
maximum P24Vin
maximum output current
2 A
Others
Internal free-wheeling path; internal filter circuit;
short-circuit proof
Connection
1
2
X1C
U
_dc
= 24 V
I
_max
= 2 A
+
-
Abb. 6:
Connection of a brake