PrODUcT DeScrIPTION
2.4 Part code
x x F 6 x x x - x x x x
Heat sink version
1: Air-cooler (water), mounted version
2: Liquid cooler (water), mounted version
3: Air-cooler, through-mount version IP54
4: Liquid cooler (water), through-mount version IP54
5: Air-cooler, through-mount version IP20
6: Liquid cooler (water), trough-mount version IP54, sub-
mounted braking resistors
7: Liquid cooler (oil), through-mount version IP54
9: Liquid cooler (water), mounted version, sub-mounted
braking resistors
A: Liquid cooler (water), trough-mount version IP54, sub-
mounted braking resistors version 2
B: Liquid cooler (water), mounted version, sub-mounted
braking resistors version 2
Control board variant
APPLIKATION
1: Multi Encoder Interface, CAN
®
2)
, Real-Time Ethernet-
busmodule
3)
KOMPAKT
1: Multi Encoder Interface, CAN
®
2)
, STO, EtherCAT
®
1)
2: Multi Encoder Interface, CAN
®
2)
, STO, VARAN
PrO
3: Multi Encoder Interface, CAN
®
2)
, Real-Time Ethernet
interface
3)
, RD485-potential free
4: No Encoder, CAN
®
2)
, Real-Time Ethernetinterface
3)
,
safe relay
5: Multi Encoder Interface, CAN
®
2)
, Real-Time Ethernet
interface
3)
, Safety Relay
Switching frequency,
Software current limit,
Turn-off current
0: 2 kHz / 125% / 150%
6: 8 kHz / 150% / 180%
1: 4 kHz / 125% / 150%
7: 16 kHz / 150% / 180%
2: 8 kHz / 125% / 150%
8: 2 kHz / 180% / 216%
3: 16 kHz / 125% / 150%
9: 4 kHz / 180% / 216%
4: 2 kHz / 150% / 180%
A: 8 kHz / 180% / 216%
5: 4 kHz / 150% / 180%
B: 16 kHz / 180% / 216%
Voltage /
Connection type
1: 3ph 230 V AC/DC with braking transistor
2: 3ph 230 V AC/DC without braking transistor
3: 3ph 400 V AC/DC with braking transistor
4: 3ph 400 V AC/DC without braking transistor
Housing
2…9
Equipment
0: Without safety function
1: Safety module type 1 / STO at control type K
3: Safety module type 3
4: Safety module type 4
5: Safety module type 5
Control type
A: APPLICATION
K: COMPACT
P: PRO