3 Technical Data
Unless otherwise indicated, all electrical data in the following chapter refer to a 3-phase
AC mains.
3.1 Operating conditions
3.1.1 climatic environmental conditions
Storage
Standard
class
Descriptions
Surrounding temperature
1K4
-25…55 °C
Relative humidity
1K3
5…95 % (without condensation)
Storage height
–
–
Max. 3000 m above sea level
Transport
Standard
class
Descriptions
Surrounding temperature
2K3
-25…70 °C
Relative humidity
2K3
95 % at 40 °C (without condensation)
Operation
Standard
class
Descriptions
Surrounding temperature
3K3
5…40 °C (extended to -10…45 °C)
Coolant inlet tem-
perature
Air
–
–
5…40 °C (-10…45 °C)
Liquid
–
–
5…40 °C
Relative humidity
3K3
5…85 % (without condensation)
Version and degree of protection
IP20
Protection against foreign material >
ø12.5 mm
No protection against water
Non-conductive pollution, occasional con-
densation when PDS is out of service.
Drive converter generally, except power con-
nections and fan unit (IPxxA)
Site altitude
–
–
Max. 2000 m above sea level
• With site altitudes over 1000 m a derat-
ing of 1 % per 100 m must be taken into
consideration.
• With site altitudes over 2000 m, the con-
trol board to the mains has only basic
isolation. Additional measures must be
taken when wiring the control.
Table 2:
Climatic environmental conditions