ANTRIEBSTECHNIK
GB 35
GB
8. Parameter
Description
Unit:
meter per second
2
Value range:
0,10...2,00 m/s
2
Factory setting:
0,90 m/s
2
Adjustment value:
according to comfort
Empirical values: 0,5...0,8 m/s
2
for retirement homes, hospitals,
apartment buildings
0,8...1,2 m/s
2
for office buildings, banks etc
Acceleration
Deceleration Jerk
Unit:
meter per second
3
Value range:
off, 0,11...9,99 m/s
3
Factory setting:
1,00 m/s
3
Adjusted value:
according to comfort
When the deceleration jerk is set too low, parameter
LF.53 is no longer valid.
Deceleration
Unit:
meter per second
2
Value range:
0,10...2,00 m/s
2
Factory setting:
0,90 m/s
2
Adjusted value:
according to comfort
Stopping Jerk
The stopping jerk determines the ride comfort as it lowers onto the
floor from the path optimization. If the setting LF.54 = off, then the
stopping jerk = deceleration jerk (LF.52)
Level Brake
Unit:
meter per second
Value range:
off, 0,02...9,99 m/s
Factory setting:
off
Adjustment value:
according to comfort
Unit:
meter per second
Value range:
0,000...0,010 m/s
Factory setting:
0,005 m/s
Adjustment value:
0,005 m/s