GB 6
GB
3. Inputs/Outputs
3.1
Terminal X2
Control Terminals
Terminal
Function
1
Control Release
2
Reset
digital inputs:
3
Direction of travel forward
noise immunity: 2 kV
4
Direction of travel reverse
logic 1:
±
12…30 V
5
Control Mode
internal input resistor: approx. 2 k
Ω
6
Door drive active
PNP-logic
7
Door drive setpoint input
8
Digital output signal: braking control
see page E 10
9
Digital output signal: main protection control inverted
see page E 10
10
+ 18 V voltage output
+18V (+/- 20%) ; max. 20 mA
! When external voltage is connected to
11
Ground for X2.10 and digital inputs/outputs
terminal X2.23 then U
X2.10
≈≈≈≈≈
U
X2.23
!
12
+10 V reference voltage
+10V (+/- 3%) ; max. 6 mA
13
Ground for analog inputs/outputs
14
Differential voltage input / resolution: 12 Bit
Analog setpoint input (see parameter LF.2)
Ri = 40 k
Ω
15
Smoothing time: 2 ms / processing time: 1...3 ms
16
Analog input of the precontrol torque
(see parameter LF.30 and LF.67)
17
Option ! do not connect !
18
Analog output set speed
-10V…+10V / resolution: 8 Bit
Ri = 100
Ω
conditional short-circuit proof( <1 min )
19
Analog output actual speed
0...10V
=
0...2 x synchronous speed
20
30 VDC / 1 A
21
Relay control cabinet fan control (LF.66)
see page E 17
22
23
External voltage supply
+ 24 ... + 30 V external voltage input
for digital outputs on terminal strip X2
^
Summary of Contents for COMBIVERT F4-F