GB-20
X2 Output State
Terminal X2 (upper terminal)
With the X.2 output state it can be easily checked, whether the outputs
were set by the inverter control. Every digital output has a specific
value. If several outputs are set at the same time, the sum of the values
is shown.
Value table:
Operating Parameter
Terminal X2 (upper terminal)
With the X.2 input state it can be easily checked, whether the input
signals reached the inverter control. Every input (output) has a specific
value. If several inputs are set, the sum of the values is shown.
Value Table:
X2 Input State
Example: Input control release (X2.1) and direction forward (X2.3) are
triggered with 24V .
Display value: 1+4 = 5
4.
Operating Parameter
Display
Valency
Function
Output
Combivis
> G
D + E
terminal
O1
1
digital
X2.8
output signal:
braking control
O2
2
digital
X2.9
output signal:
main contactor
main contactor
control inverted
control
O3
4
relay
relay ready-to-operate X2.20/X2.22
control cabinet fan
collective fault
overspeed
Display
Valency
Function
Input
Combivis
> G
D + E
terminal
ST
1
control release
X2.1
RST
2
Reset
X2.2
F
4
direction of travel forward
X2.3
R
8
direction of travel reverse
X2.4
I1
16
control mode
X2.5
I2
32
door drive active
setpoint selection
X2.6
I3
64
door drive setpoint setting
binary-coded
X2.7