GB-4
Inputs / Outputs
1.1
Terminal X2 Control Terminals (units > G-housing)
1.
Inputs / Outputs
Terminal
Function
1
Control Release
2
Reset
digital inputs:
3
Direction of travel forward
noise immunity: 2 kV
4
Direction of travel reverse
logic 1:
±
12…30 V
5
Control Mode
internal input resistor: approx. 2 kOhm
6
Door drive active
PNP-logic
7
Door drive setpoint input
8
Digital output signal: speed deviation, warning
see chapter 3.4
9
Digital output signal: main contactor control inverted
see chapter 3.4
10
+ 18 V voltage output
+18V (+/- 20%) ; max. 20 mA
! When external voltage is connected to
11
Ground for X2.10 and digital inputs/outputs
terminal X2.23 then U
X2.10
≈≈≈≈≈
U
X2.23
!
12
+10 V reference voltage
+10V (+/- 3%) ; max. 6 mA
13
Ground for analog inputs/outputs
14
Differential voltage input -10V ... +10V
Analog setpoint input
resolution:12 Bit Ri = 40 kOhm
15
(see parameter LF.2 and An-parameter)
Smoothing time: 2 ms / processing time: 1...3 ms
16
Analog input of the load measure for pretorque
Differential voltage input -10V ... +10V
(see parameter LF.30, LF.67 and
resolution:12 Bit Ri = 40 kOhm
17
An-parameter)
Smoothing time: 2 ms / processing time: 1...3 ms
18
Analog output set speed
-10V…+10V / resolution: 8 Bit
Ri = 100 Ohm
conditional short-circuit proof ( <1 rpm)
19
Analog output actual speed
0...10V
^
0...LF.20
20
30 VDC / 1 A
21
Relay output for cabinet fan control (LF.66)
see chapter 6.1
22
23
External voltage supply
+ 24 ... + 30 V external voltage input
for digital outputs on terminal strip X2
Summary of Contents for COMBIVERT F4-F