6
3
KEB COMBIVERT F5
8
Name: Basis
28.01.03
Chapter
Section
Page
Date
©
KEB Antriebstechnik, 2002
All rights reserved
Functional Description
Digital In- and Outputs
6.3.11 Assignment of
the Inputs
An. 3
AN1 save trigger / input selection
An.13
AN2 save trigger / input selection
An.23
AN3 save trigger / input selection
cn.11
PID reset / input selection
cn.12
I reset / input selection
cn.13
Fade in reset / input selection
di. 9
Reset / input selection
Fr. 7
Parameter set / input selection
Fr.11
Reset set / input selection
LE.17
Timer 1 Start / input selection
LE.19
Timer 1 Reset / input selection
LE.22
Timer 2 Start / input selection
LE.24
Timer 2 Reset / input selection
oP.19
Fixed value / input selection 1
oP.20
Fixed value / input selection 2
oP.56
Motorpoti increase / input selection
There are two different procedures for the assignment of inputs. Both variants are
locked against each other to give the user maximum flexibility.
List of parameters, that can be assigned with inputs:
The internal input status shows the logic condition of the digital inputs which are
internally set for processing. It is unimportant, whether the external terminals are
active or not. If an input is set, the appropriate decimal value according to the table
under 6.3.8 is output. If several inputs are set, then the sum of the decimal values is
output.
With di.9 the reset input is defined according to the table under 6.3.8. If the reset input
shall react to an edge, one or several of the reset inputs defined with di.9 can be
switched to edge evaluation with di.10.
6.3.9
Input Status
(ru.22)
6.3.10 Reset/Input
Selection and
Edge Evaluation
(di.9 / di.10)
1)
By selecting the source of rotation (oP.1) the adjustment can be changed from forward/
reverse to Run/Stop.
oP.57
Motorpoti decrease / input selection
oP.58
Motorpoti Reset / input selection
oP.60
1)
Rotation forward (Run) / input selection
oP.61
1)
Rotation reverse (Stop) / input selection
Pn. 4
External fault / input selection
Pn.23
Ramp stop / input selection
Pn.29
DC-braking / input selection
Pn.64
set GTR7 input selection
PS.2
pos/sync input select
PS.3
shift. slave input selection
PS.10
shift slave invers input selection
PS.18
reference switch input selection
PS.19
start reference input selection
PS.29
start posi input selection
uF. 8
Energy-saving function / input selection
di.24
I1 prog. function
di.25
I2 prog. function
di.26
I3 prog.function
di.27
I4 prog.function
di.28
IA prog.function
di.29
IB prog.function
Additional functions
Parameters can be allocated with one additional function each. The parameters are
firmly assigned to the prefixed inputs and are activated by setting bit 31.
di.30
IC prog.function
di.31
ID prog.function
di.32
FOR prog.function
di.33
REV prog.function
di.34
RST prog.function
di.35
ST prog.function
Value
Function
0
PS.11
Reset Master/Slave Difference / input selection
1
PS.13
Set reference point / input selection
2
PS.36
Teach position / input selection