KEB COMBIVERT F5
10
Name: Basis
04.05.04
©
KEB Antriebstechnik, 2002
All Rights reserved
Product Description
Summary
Chapter
Section
Page
Date
20
21
22
23
24
R
R
R
R
U
R
U
3
3
3
3
3
[kVA] 52
62
80
104
125
[kW] 37
45
55
75
90
[A] 75
90
115
150
180
[A] 112
135
172
225
270
[A] 135
162
207
270
324
[A] 83
100
127
165
198
[A] 100
160
160
200
315
[kHz]
8
4
8
4
8
2
8
2
4
8
[kHz] 16
16
16
12
8
8
[W] 900 1000 1100 1200 1500 1300 1900 1700 2000 2400
[A] 75
90
115 115
127,5
150 144
180
[A] 75
63
90
80
115 90 150 108
180
[A] 34
45
54
46
51
-
-
-
-
[
∞
C]
90
[mm
≤
] 35
50
50
95
95
[Ohm]
9
6
5
4
[Ohm] 12
10
8,6
6,7
5
[A]
88
133 160
200
1
[Nm]
6
15
Inverter Size
Housing size
Phases
Output nominal power
Max. rated motor power
Output nominal current
Max. short time current
1)
OC-tripping current
Nominal input current
Max. permissible mains fuse (inert)
Rated switching frequency
Max. switching frequency
Power loss at nominal operating
Stall current at 4kHz
2)
Stall current at 8kHz
2)
Stall current at 16kHz
2)
Max. heat sink temperature TOH
Motor line cross section
3)
Min. braking resistor
4)
Typ. braking resistor
4)
Max. braking current
Overload curve (page appendex)
Tightening torque for terminals
Mains voltage
5)
Mains frequency
Output voltage
Output frequency
Max. shielded motor line length
Storage temperature
Operating temperature
Model / protective system
Relative humidity
EMC tested according to
Climatic category
[V]
305...500 ±0 (400 V Nominal voltage)
[Hz]
50 / 60 +/- 2
[V]
3 x 0...U Mains
[Hz]
see Control board
[m]
50
[
∞
C]
-25...70
∞
C
[
∞
C]
-10...45
∞
C
-10...40
∞
C
IP20
max. 95% without condensation
EN 61800-3
3K3 in accordance with EN 50178
1) With the regulated systems F5-M as well as F5-S 5% are to be subtracted as control reserve.
2) Fuses of type Ferraz Shawmut 6,6 UD Type 31
3) Max. current before the responding of the OL2-function (only F5-M; F5-S; F5-A)
4) Recommended minimum cross section for rated power and a cable length of upto 100m (copper)
5) This data is only valid for units with internal brake transistor (see "unit identification")
6) Rated voltage 400V; at mains voltage
≥
460V multiply the rated current with factor 0.86.
7) The temperature range is only valid for the control circuit. For the power circuit the temperature range is depending on
the control cabinet installation and the cooling system.
8) 31.F5 only watercooled.