Functional Description
Special Functions
The drive runs with different speed back and forth and always reverses at the same
points.
Downloadlist:
Set
Parameter
Value
Notes
0
Ud01
Password
440
0
Fr01
Copy parameter set
-2: def. cust.para all sets
0-3
oP00
Reference source
0: Analog REF
0-3
oP01
Rotation source
0: dig.(op.2), 0-lim.
0
oP02
Rotation setting
1: forward
Set 0: clockwise rotation
1
oP02
Rotation setting
0: low speed
Set 1: clockwise rotation positioning
2
oP02
Rotation setting
2: reverse
Set 2: counterclockwise rotation
3
oP02
Rotation setting
0: low speed
Set 3: counterclockwise positioning
0-3
oP10
Max. reference forward
70,0000 Hz
The max. setpoint value must be the
same in all sets.
0-3
oP11
Max. reference reverse
-1: = see oP.10 The max. setpoint value can be different
for the direction of rotation.
0-3
oP28
Acc. time forward
0,10 s
0-3
oP30
Dec. time forward
0,10 s
0
Pn63
Positioning delay
-1: off
1
Pn63
Positioning delay
0,8 s
Shifting of the position at clockwise
rotation
2
Pn63
Positioning delay
-1: off
3
Pn63
Positioning delay
3,1 s
Shifting the position at counterclockwise
rotation
0
Fr02
Parameter set source
2: terminal binary coded
0
Fr05
Set activation delay
0,00 s
Additional break between counter-
clockwise and clockwise rotation
1
Fr05
Set activation delay
0,00 s
This time must be = 0
2
Fr05
Set activation delay
0,00 s
Additional break between clockwise and
counterclockwise rotation
3
Fr05
Set activation delay
0,00 s
This time must be = 0
0
Fr06
Set deactivation delay
0,00 s
This time must be = 0
1
Fr06
Set deactivation delay
1,00 s
Break between clockwise and
counterclockwise rotation
2
Fr06
Set deactivation delay
0,00 s
This time must be = 0
3
Fr06
Set deactivation delay
1,00 s
Break between counterclockwise and
clockwise rotation
0
Fr07
Para. set input selection
272: I1+IA
0
Fr11
Reset set input selection
0: no input
0
di11
I1 Function
2048: Set sel.
Initiator signal
0
di15
IA Function
2048: Set sel.
Changeover between clockwise and
counterclockwise rotation
0
do04
Condition 1
0: off
Initiator active: -> set 1
1
do04
Condition 1
1: on
Positioning completed: -> set 2
2
do04
Condition 1
1: on
Initiator active: -> set 3
3
do04
Condition 1
0: off
Positioning completed: -> set 0
Exsample 2