Parameter
5
1
13
KEB COMBIVERT F5-G / C / B
Name: Basis
10.05.04
Section
Page
Date
©
KEB Antriebstechnik, 2002
All Rights reserved
Chapter
Parameter
Adr.
Control Properties min.
max.
Step default [?] see on Page
5
uf 0 rated frequency
05 00 B C g G M - A - P - V 0
400
0,0125
50
Hz
6.5.4
uf 1 boost
05 01 B C g G M - A - P - - 0,0
25,5
0,1
2,0
%
6.5.4
uf 2 add. frequency
05 02 B C g G M - A - P - V -1
400
0,0125
0:off
Hz
6.5.4
uf 3 add. voltage
05 03 B C g G M - A - P - - 0,0
100,0
0,1
0,0
%
6.5.4
uf 4 delta boost
05 04 B C g G M - A - P - - 0,0
25,5
0,1
0,0
%
6.5.4
uf 5 delta boost time
05 05 B C g G M - A - P - - 0,00
10,00
0,01
0,00
s
6.5.4
uf 6 energy saving mode
05 06 B C g G M - A - P - - 0
7
1
0
-
6.9.5
uf 7 energy saving factor
05 07 B C g G M - A - P - - 0,0
130,0
0,1
70,0
%
6.9.5
uf 8 energy saving input sel.
05 08 B C g G M - A - - E - 0
4095
1
0
-
6.9.5, 6.3.8
uf 9 voltage stabilisation
05 09 B C g G M - - - P E - 1
650:off
1
650:off
V
6.5.5
uf 10 max. voltage mode
05 0A - C - G M - A - P - - 0
3
1
0
-
6.5.6
uf 10 max. voltage mode
05 0A B - g - - - - - P - - 0
2
1
0
-
6.5.6
uf 11 carrier frequency
05 0B B - g G M S A - P E - 0
LTK
1
LTK
-
6.5.6
uf 12 base block time
05 0C B - g G M S A R - - - LTK
LTK
0,01
LTK
s
6.7.9
uf 13 base block voltage level
05 0D B - g G M S A R - - - LTK
LTK
1
LTK
%
6.7.9
uf 15 hardw. curr. lim. mode
05 0F - - - G M S A - - - - 0
2
1
1
-
6.7.3
uf 15 hardw. curr. lim. mode
05 0F B - g - - - - - - - - 0
1
1
1
-
6.7.3
uf 16 autoboost configuation
05 10 B - g G - - A - P - - 0
3
1
0
-
6.11.4
uf 17 autoboost gain
05 11 B C g G - - A - P - - 0,00
2,50
0,01
1,20
-
6.11.4
uf 18 deadtime comp. mode
05 12 B C g G M - - - - - - 0
1
1
1
-
6.7.9
uf 19 volt.stab.PT1-timeconst.
05 13 - - - G - - A - - - - 0
10
1
0
-
6.5.5
uf 20 KI Offset-Control
0514 - - - - - - - - - - - 0
32767
1
50
-