138
LI - Input Parameters
Allows a custom input logic table t
o be defined for binary speed control mode, US04
Control Type = Binary Speed Selection (1).
This parameter must be adjusted as
a hexadecimal number using the NUM function on the keypad when editing.
To select this function, set LI03 Speed Input Decoding = Decode with LI16.Speeds
are assigned the following values:
2
=
Leveling
4
=
Correction
6
=
Inspection
8
=
High
A
=
Intermediate
1
C
=
Intermediate
2
E
=
Intermediate
3
The parameter is 7 digits, populated one digit at a time with the above values to
create the decoding. The first, right-most digit corresponds to binary 001 and the
seventh, left-most digit corresponds to binary 111 where I8>...>I1. Zero speed is fixed
with binary 000.
I4
I3
I2
Digit
0
0
0
-
0
0
1
1 (Right-most)
0
1
0
2
0
1
1
3
1
0
0
4
1
0
1
5
1
1
0
6
1
1
1
7 (Left-most)
For example, the binary input logic table corresponding to the default setting of LI03
Speed Input Decoding = B(Level - Correction - Inspection), NUM = 0, would be LI16
= ECA8642 (note the order of the inputs).
Binary Speed
Selection
Parameter
Control Inputs
LI16 Value
I2
I3
I4
S
Z
ERO
-
x
x
x
-
S
L
EVELING
LS01
1
0
0
2
S
C
ORRECTION
LS02
0
1
0
4
S
I
NSPECTION
LS03
1
1
0
6
S
H
IGH
LS04
0
0
1
8
S
I
NTERMEDIATE
1
LS05
1
0
1
A
S
I
NTERMEDIATE
2
LS06
0
1
1
C
S
I
NTERMEDIATE
3
LS07
1
1
1
E
LI16
Custom Input
Decoding