Diagnosis/visualisation X4A | 6
ma_dr_f6-cu-p-inst-20182705_en
27
6 Diagnosis/visualisation X4A
The integrated serial interface provides the following functions:
• Parameterization of the device with the KEB software
• Connection of a control operator.
• DIN66019II as communication protocol.
Interface
Specification
RS485
Common-mode voltage range 0…12 V
RS232
ANSI TIA/EIA-232
Tab. 11:
Serial interfaces
Name
Material number
RS232 PC inverter (SubD-9 coupling -
SubD-9 plug)
0058025-001D
RS232/USB (USB serial converter in-
clusive cable)
0058060-0040
Tab. 12:
Connecting cable
ACHTUNG
No potential separation of the diagnostic interface to the control voltage!
Malfunction or defect caused by voltage differences.
a) Install equipotential bonding conductor if voltage differences > common-mode
signal.
XML file required for COMBIVIS 6.
a) A current XML file is required for the operation with COMBIVIS 6.
b) The download can be done directly from COMBIVIS 6 while an Internet con-
nection is present.
6.1 Assignment of the terminal strip X4A
5 4 3 2 1
9 8 7 6
1
2
3
4
5
6
7
8
9
Abb. 1:
Pin assignment socket D-Sub-9 (top view)
1 reserved
2 TxD (RS232)
3 RxD (RS232)
4 RxD-A (RS485)
5 RxD-B (RS485)
6 reserved
7 DGND (reference potential)
8 TxD-A (RS485)
9 TxD-B (RS485)
6.2 Data cable RS232 PC-Drive Controller
0058025-001D
1
5
6
9
1
5
6
9
Abb. 2:
Serial cable for the connection to a PC