Parameter sets
© KEB, 2008-02
COMBIVERT R6-S
Page3.7 - 5
3
10
3.7.5 Copy parameter sets via bus (Fr.01, Fr.09)
With indirect set addressing two parameters are responsible for copying parameter sets at bus operation. Fr.09
determines the target set. Fr.01 determines the source parameter set and starts the copy process. With direct
set-programming the source set (Fr.01) is copied in the selected parameter sets. The following copy functions
can be executed:
Target set
Fr.09
Source set
Fr.01
Action
0...7
0...7
All set-programmable parameters (also system parameters) of the source
set are copied in the target set.
0
-1: dEF_S
Default values are copied in all parameters of set 0 (exception system and
security parameters).
1...7
-1: dEF_S
Default values are copied in all set-programmable parameters of the target
set (exception system and security parameters).
All
-2: dEF_A
Default values are copied in all parameters of all sets (exception system
and security parameters).
0
-3: ini_S
Default values are copied in all parameters of set 0 (exception security
parameters).
1...7
-3: ini_S
Default values are copied in all set-programmable parameters of the target
set (exception security parameters).
All
-4: ini_A
Default values are copied in all parameters of all sets (exception security
parameters).
All definitions defined by the machine builder are reset by loading the factory setting
! This can include the ter-
minal assignment, set changeover or operating conditions. Ensure before loading the default set that there are
no unwanted operating conditions.
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......