Define CP-Parameters
© KEB, 2008-02
COMBIVERT R6-S
Page 3.9 - 3
3
10
3.9 Define CP-Parameters
If the development stage of a machine is completed, usually only a few parameters are required to adjust or
control the COMBIVERT. In order to simplify the handling and end-user documentation, as well as the security
against unauthorized access, there is the possibility to create an own user interface, the CP-Parameters. 37
parameters (CP.00...CP.36) are available for this, 36 parameters (CP.01...CP.36) can be assigned free.
3.9.1 Overview
Picture 3.9.
1 Definition structure
CP.0 / ud.1
ud.15
ud.17
ru.3
ud.16
ud.17
ru. 3
ud.16
ud.17
An.32
CP.1
CP.2
CP.36
440
330
200
100
500
ud.16
1
2
36
Application mode
Service mode
Reading /
writing
read-
only
Drive
mode
Password
CP mode
Address
Set / norm
Address
Address
Set / norm
Set / norm
ud.15 determines the CP-Parameter to be processed. With ud.16 and
ud.17 the CP-Parameter is defined by its
address, the respective set and the display norm. Dependent on the adjusted password (CP.00 or ud.01)
- the adjusted parameter is directly displayed in the service mode
- the adjusted parameter is displayed as CP-Parameter in the CP mode
Parameter CP.00 is not configurable, it always includes the password
input. ud.01 is used for password input if
the inverter is in application or service mode.
Parameters which are not permissible as CP-Parameters (e.g.
ud.15 ... 17 and Fr.1) are confirmed with "
data
invalid". Input of an invalid parameter address switches the parameter to "oFF" (-1). The corresponding CP-
Parameter is not displayed in this setting.
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......