Page 3.9 - 8
COMBIVERT R6-S
© KEB, 2008-02
Define CP-Parameters
Bit 12...15 Bit 11...8
Bit 7...6
Bit 5...0
ud.21
-
-
-
see table 1
Unity
-
-
see table 2
-
Mode of calcula-
tion
-
see table 3
-
-
Display
free
-
-
-
-
Table 1 unity (bit 0...5)
Value
Unity
Value
Unity
Value
Unity
Value
Unity
0
no
16
km/h
32
K
48
lbin
1
mm
17
1/min
33
m
W
49
in/s
2
cm
18
Hz
34
W
50
ft/s
3
M
19
kHz
35
k
W
51
ft/min
4
km
20
mV
36
inc
52
ft/s²
5
G
21
V
37
%
53
ft/s³
6
kg
22
kV
38
kWh
54
MPH
7
us
23
mW
39
mH
55
kp
8
ms
24
W
40
-
56
psi
9
s
25
kW
41
-
57
°F
10
h
26
VA
42
in
58
-
11
Nm
27
kVA
43
ft
59
-
12
kNm
28
mA
44
yd
60
-
13
m/s
29
A
45
oz
61
-
14
m/s
2
30
kA
46
lb
62
-
15
m/s
3
31
°C
47
lbft
63
-
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......