Fundamentals
© KEB, 2008-02
COMBIVERT R6-S
Page 2.1 - 5
2
10
2.1.4 ENTER parameters
For some parameters it is not reasonable that the selected values are immediately active. They are called
ENTER parameters, because they become active only after confirming with the ENTER key.
2.1.5 Not set-programmable parameters
Certain parameters are not set-programmable, since their value must be the same in all sets (e.g. bus address
or baud rate). The parameter set number is missing in the parameter identification in order that these parame
-
ters are immediately visible.
Always the same value is valid for all non set-programmable parameters independent of the selected
parameter set!
2.1.6 Reset of error messages
If a malfunction occurs during operation, then the actual display is overwritten by a flashing alarm message.
The error message can be deleted by pressing the ENTER key, so the original value is displayed again.
Attention!
Resetting the error message with ENTER is not an error reset, i.e. the error status in the inverter
is not reset. Thus it is possible to change adjustments before the error reset. An error reset is only possible by
reset terminal or control release.
2.1.7 Reset of peak values
There are parameters which display the peak values to draw conclusions from the operational performance of
a drive. Peak value means the highest measured value is stored for the ON time of the inverter (slave pointer
principle). The peak value is deleted and the actual measured value is displayed by pressing ▲ or ▼ .
2.1.8 Acknowledge of feedbacks
Some parameters send a feedback in order to monitor the proper operation. Par example, the display "PASS"
indicates after copying a set, that the operation was completed error free. These feedbacks must be accepted
with ENTER.
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......