Seite 3.6 - 4
COMBIVERT R6-S
© KEB, 2008-02
Protective functions
Unity of the pre-warning
Pre-warning period or level adjustable
Pre-warning possible via digital output
Function can be switched off
Automatic restart adjustable
Error without adjustable response
Message
Operator
Value Message COMBIVIS
E.buS/ A.buS
18/93
Error!/warning! watchdog
-
• •
-
•
s
E.dOH/ A.dOH 9/96
Error!/warning! temperature of the commutation choke -
• • • •
s
E.EEP
21
Error! EEPROM defective
•
- - - -
-
E.EF/ A.EF
31/90
Error!/warning! ERROR external fault
-
• •
- -
-
E.LSF
15
Error! load shunt fault
•
- - - -
-
E.nEt
3
Error! Net
•
- - - -
-
E.OC
4
Error! overcurrent
-
•
- - -
-
E.OH/ A.OH
8/89
Error!/warning! Power module temperature
-
•
-
• •
°C
E.OHI/ A.OHI
6/87
Error!/warning! interior temperature
-
• • • •
s
E.OL/ A.OL
16/99
Error!/warning! overload (Ixt)
-
•
-
• •
%
E.OP
1
Error! overvoltage
-
•
- - -
-
E.PU
12
Error! defective in power unit
•
- - - -
-
E.Puch
50
Error! power unit code changed
•
- - - -
-
E.PucI
49
Error! power circuit unknown
•
- - - -
-
E.PUIN
14
Error! power unit coding
•
- - - -
-
E.SEt/ A.SEt
39/102
Error!/warning! set
-
• •
- -
-
E.SYn
59
Error! synchronization
•
- - - -
-
E.UP
2
Error! underpotential
-
•
- - -
-
F.nEt
40
Error! mains frequency
•
- - - -
-
3.6.1.1 Undervoltage
„Error! Undervoltage“ (E.UP) is triggered if the DC link voltage drops due to brownouts or a generally too weak
power grid. For this error, the automatic restart can be activated.
3.6.1.2 Overvoltage
„Error! Overvoltage“ is triggered if the DC link voltage increases beyond the overvoltage level.
3.6.1.3 Overcurrent
The „Error! Overcurrent“ (E.OC) is triggered, if the „OC tripping current“ (see technical data in the instruction
manual) is exceeded.
If this error occurs permanently, either the parameter setting is not correct or the COMBIVERT is defective.
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......