Special functions
© KEB, 2008-02
COMBIVERT R6-S
Page 3.8 - 3
3
10
3.8 Special functions
The following section should facilitate the adjustment and programming of special functions.
3.8.1 Program timer / counter
Two timers are incorporated in the COMBIVERT. As long as one of the adjustable starting conditions (LE.18/
23) or a programmable input (LE.17/ 22
) is set, the timer counts until reaching the final range value. If one of the
reset conditions (LE.20/ 25) is met or one programmable input (LE.19/ 24) is set, the timer jumps back to zero.
The clock source and the counting direction is adjusted with LE.21/ 26. It can be counted in seconds, hours or
by a special programmed input for that. The current timer content is displayed in ru.43/44. Switching condition
37/ 38 is set with reaching an adjustable switching level (LE.00...07). It can be used to set an output.
Picture 7.15.4 Timer programming
Switching condition
37 „Timer 1 > Level A“
is being set!
Timer value > level
LE.0...LE.7 ?
Is a
reset condition
of LE.20 or LE.19
met ?
Timer counts up to maximum
value; down to 0, if a condition
of LE.18 is met or an input of
LE.17 is set
ru.43
Timer 1 display
no
LE.21 Timer 1 /
Mode
no
yes
yes
Resetting to zero
continues to count
Switching condition
38 „Timer 2 > Level A“
is being set!
Timer value > level
LE.0...LE.7 ?
Is a
reset condition
of LE.25 or LE.24
met ?
Timer counts up to maximum
value; down to 0, if a condition
of LE.23 is met or an input of
LE.22 is set
ru.44
Timer 2 display
no
LE.26 Timer 2 /
Mode
no
yes
yes
Reset to zero
continues to count
I3
I4
Summary of Contents for combivert R6-S
Page 1: ...APPLICATION MANUAL Mat No Rev 00R6SEA K130 1 A GB KEB COMBIVERT R6 S Version 1 3 ...
Page 2: ...Page 1 1 2 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 4: ...Page 1 1 4 COMBIVERT R6 S KEB 2008 02 Introduction ...
Page 14: ...Page 1 2 6 COMBIVERT R6 S KEB 2008 02 Product overview ...
Page 28: ...Page 2 1 6 COMBIVERT R6 S KEB 2008 02 Fundamentals ...
Page 34: ...Page 2 2 6 COMBIVERT R6 S KEB 2008 02 Password structure ...
Page 116: ...Page 3 8 2 COMBIVERT R6 S KEB 2008 02 Special functions 3 8 1 Program timer counter 3 8 3 ...
Page 130: ...Page 3 9 10 COMBIVERT R6 S KEB 2008 02 Define CP Parameters ...
Page 140: ...Page4 2 2 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 144: ...Page4 2 6 COMBIVERT R6 S KEB 2008 02 Start up ...
Page 150: ...Page 5 1 6 COMBIVERT R6 S KEB 2008 02 Error assistance ...
Page 158: ...Page 6 1 8 COMBIVERT R6 S KEB 2008 02 Project design ...
Page 160: ...Seite 7 1 2 COMBIVERT R6 S KEB 2008 02 Annex 7 1 1 Keyword index 7 1 3 ...
Page 166: ......
Page 167: ......