2.3 Unintended use
Means:
• The COMBIVERT T6
APD
may not be used as AIC (Active Infeed Controller).
• The COMBIVERT T6
APD
may not be operated without restrictions on an AIC (Ac-
tive Infeed Controller).
•
Operation outside the limit values specified in the technical data.
• Operation of socket consumers at the output of the module without mains simula-
tion.
Improper use by the customer, user or other third parties leads to the loss of all claims
against the manufacturer.
2.4 Overview of the COMbIVERT T6
APD
X3A
X1A
X2A
X1B2…max. X1B6
X1B1
IN
OUT
Legend
1
Nameplate
2
Central ground connection, connection for protective earth, =>
3
Pressure compensation valve for the housing
X1A
Connector for control signals, LV-DC input (electrical system), HVIL, CAN and KEB diagnosis
X2A
Ethernet interface RJ45
X3A
HV-DC input
X1B1...X1B6 Motor output, number according to installed inverter modules (max. 6)
IN
Coolant inlet (connection G 1/4)
OUT
Coolant outlet (connection G 1/4)
Figure 2:
T6
APD -
Complete overview
30
PRODUCT DESCRIPTION