The total power dissipation in the LV-DC circuit of a T6
APD
is shown in the following table
depending on the system type.
T6
APD
system
Inverter modules
Length
Power input
PLV-DC
System length
Number
in mm
in W
A
1
346
14
B
2
496
24
C
3
646
35
D
4
796
45
E
5
946
55
F
6
1096
65
Table 12:
Power input of the modules
3.2.5 Inverter modules A, b, C
Module
A
b
C
Max. rated motor power (asynchronous)
P
mot
/ kW
7,5
15
30
Rated output current at
f
S
= 8 kHz
I
N
/ A
16,5
33
60
Output voltage
U
out
/ V
3 x 0…
U
in_dc
/ √2
Output frequency
2)
f
out
/ Hz
0...599
Output phases
3
Overload current (60 s)
I
60s
/ %
150 x
I
N
110 x
I
N
Overload current (1 s)
I1s
/ %
170 x
I
N
125 x
I
N
Overcurrent
I
OC
/ %
180 x
I
N
133 x
I
N
Rated switching frequency
f
SN
/ kHz
8
Max. switching frequency
3)
f
S_max
/ kHz
16
Overload current over time
I
OL
/ %
„3.2.5.1 Overload characteristic (OL)“
Maximum current
I
f0/Ifd
/ %
=>
„3.2.5.2 Frequency-dependent maximum
Power dissipation at rated operation
4)
P
D
/ W
239
462
808
Table 13:
Electrical data of the inverter modules
1)
The protection functions are designed for rated operation with 8 kHz.
2)
The output frequency is to be limited in such a way that it does not exceed 1/10 of the switching frequency.
Units with higher max. output frequency are subject to export restrictions and are only available on request.
3)
A detailed description of the derating
=>
„3.2.6 Switching frequency and temperature“
.
4)
Rated operation corresponds to U
N
= 400 V; f
SN
; I
N
; f
N
= 50 Hz (typical value).
The technical data are for 2/4-pole standard motors. With other pole numbers
the inverter must be dimensioned onto the rated motor current. Contact KEB
for special or medium frequency motors.
40
SYSTEM AND MODULE DATA
Summary of Contents for COMBIVERT T6APD