4.4 Connection of the control
The following information must be observed when connecting:
NOTICE
Interference due to inductive and capacitive coupling
►
Lay control and power cable separately (about 10…20 cm distance);
Lay crossings in a right angle.
►
Use twisted bus cable.
►
Do not lay the cables for temperature monitoring of the motor (also
shielded) together with the control cables!
All connections of the connector X1A have "Safe isolation" in accordance with
4.4.1 Assignment of the connector X1A
Parts data connector X1A
Connector manufacturer
TE Connectivity
Website
Name
23-pole connector housing
Housing colour
black
Part No.
1-776087-1
PIN
Name
Description
1
LV_DC_AUX
Low voltage – voltage supply 9-32 V electrical system
(KL30g – switched positive cable directly from the battery)
2
LV_GND
Electrical system ground
(KL31 – Negative wire directly from the battery or vehicle
ground)
3
CAN_H_0
CAN-High Port 0 (CAN 2.0)
4
CAN_L_0
CAN-Low Port 0 (CAN 2.0)
5
CAN_H_0
Connection of additional CAN clients to port 0
continued on the next page
72
CONNECTION Of THE CONTROL
Summary of Contents for COMBIVERT T6APD
Page 2: ......