4.4.1.1 Terminal 15 „Enable“
Terminal 15 "Enable" is used for modulation release of the COMBIVERT T6
APD
, i.e. the
connected inverter modules can start the operation.
PIN
X1A.9
Reference
potential
X1A.2 (LV_GND)
Digital inputs
Status 0
Status 1
U
_low
/ V
I
_low
/ mA
U
_high
/ V
I
_high
/ mA
max.
6
3
32
20
min.
0
not defined
7
7
Table 26:
Specifications of the input „Enable“
+
9
2
Figure 34:
Connection of the input terminal 15 „Enable“
4.4.1.2
Specification of the CAN bus
Interface 0
CAN-high
X1A.3
CAN-low
X1A.4
Interface 1
CAN-high
X1A.7
CAN-low
X1A.8
Transmission speed
20, 25, 50, 100, 125, 250, 500, 1000 kbit/s adjustable
Potential separation
Galvanic isolation to the control potential.
Bus termination
120 Ω at both ends of the bus line;
at T6
APD
switchable by external jumper.
Differential resistance in re
-
cessive state
≥ 4 kΩ
Table 27:
Specifications of the CAN bus
74
CONNECTION Of THE CONTROL