3 Technical Data
3.1 Operating conditions
3.1.1 Evironmental conditions
Storage
Standard
Class
Notes
Environmental conditions
Code A -40…85 °C
Storage height
–
–
Max. 3000 m above sea level
Transport
Standard
Class
Notes
Environmental conditions
Code A -40…85 °C
Operation
Standard
Class
Notes
Ambient temperature
Code Z -30…70 °C
Environmental conditions
Code A -
Coolant inlet temperature
–
–
30…65 °C
Version and degree of pro-
tection
IP67
Dust-proof, complete protection against contact,
protection against temporary submersion
IP6k9k
Dust-proof, complete protection against contact,
protection against water during high-pressure /
steam cleaning
Site altitude
–
–
Max. 2000 m above sea level
Table 4:
Evironmental conditions
3.1.2 Mechanical environmental conditions
Storage
Standard
Class
Notes
Vibration limits
Code L Commercial vehicles, sprung mass
Frequency 10…2000 Hz, acceleration 57.9 m/s
2
Shock limit values
Code L Shock 6 ms, acceleration 500 m/s
2
Transport
Standard
Class
Notes
Vibration limits
Code L Commercial vehicles, sprung mass
Frequency 10…2000 Hz, acceleration 57.9 m/s
2
Shock limit values
Code L Shock 6 ms, acceleration 500 m/s
2
Operation
Standard
Class
Notes
Vibration limits
Code L Commercial vehicles, sprung mass
Frequency 10…2000 Hz, acceleration 57.9 m/s
2
Shock limit values
Code L Shock 6 ms, acceleration 500 m/s
2
Pressure in the water cooler
–
–
Rated operating pressure: 2 bar
Max. operating pressure: 4 bar
Table 5:
Mechanical environmental conditions