4.3 Connection of the power unit
Use pre-assembled cables
►
Optimal shield connection to functional earth.
►
Optimum EMC technical installation.
►
Compliance with operating conditions.
The IP protection types for the connectors always refer to the mated and locked
condition.
4.3.1 High voltage DC supply
HVIL_in
HVIL_out
HV-DC+
HV-DC-
➃ ➄
+ + +
+
➅
➆
Legend
1
Vehicle
2
Energy source (e.g. high voltage battery DC 520…750 V)
3
MCCB or relay; control e.g. from HVIL (high voltage interlock) of the vehicle
control or insulation monitor
4
Precharging circuit
5
Fuses type aR; pay attention to the permissible voltage range !=>
6
HV-DC coupling (not included in the scope of delivery)
7
KEB COMBIVERT T6
APD
Figure 20: Connection at DC voltage supply
The T6
APD
must be pre-charged via a appropriate circuit. This is to be carried
out, for example, passively with a minimum precharging resistance of 3
Ω
or
actively by means of power electronics. When dimensioning the permissible
current of the used DC fuse must be observed. This can lead to a larger mini-
mum precharging resistance.
60
CONNECTION Of THE POWER UNIT