4.3.1.4 Coupling for HV-DC supply
The following plug-in connection is not included in the scope of delivery. It is assembled
by the vehicle manufacturer or directly ordered from the specified manufacturer. It is
recommended to lay the HV-DC + and HV-DC - cables together. Only cables approved
by the manufacturer must be used.
Manufacturer data accessories
Connector manufacturer
Rosenberger
Website
Name
HVR 200; Coupler with HVIL
Protection class
IP6K9K, IPXXD, IPX8 (plugged in)
Connection cross section
16 mm², 35 mm² (depending on the design)
Mating cycles
≤ 50
Coding connector
A
Tightening torque according to
manufacturer's specification
4 Nm ± 0.4 Nm
Preload force according to
manufacturer's specification
< 75 N
1 4 3 2
Contact
Name
Description
1
HV-DC +
High voltage DC input +
2
HV-DC -
High voltage DC input -
3
HVIL_in
Is used to open the Interlock Loop
4
HVIL_out
Is used to open the Interlock Loop
Figure 24:
Coupling for HV-DC supply (counterpart for X3A)
Manufacturer part number
Cable cross-section
H2K101-W2A035B1-A
35 mm
2
H2K101-W2A016B1-A
16 mm
2
Table 21: Plug-in connector coding
The indicated article numbers are to be understood as an example.
NOTICE
Defect due to loose plug connection !
►
A correct plug-in connection is only given when the plug connector
is plugged-in and screwed with tightening torque.
63
CONNECTION Of THE POWER UNIT
Summary of Contents for COMBIVERT T6APD